From 3f64afccc40ce8f446630daa44567e5b66d01c56 Mon Sep 17 00:00:00 2001 From: umsangdon Date: Sat, 19 Sep 2026 17:38:27 +0900 Subject: [PATCH] auto: 2026-09-19 17:38 (ESD_LAPTOP) --- .../계수_건설품셈_기계설비5장.json | 138 ++++ .../계수_건설품셈_기계설비6장.json | 142 ++++ .../소요량_건설품셈_기계설비5장.json | 664 ++++++++++++++++++ .../소요량_건설품셈_기계설비6장.json | 336 +++++++++ 4 files changed, 1280 insertions(+) create mode 100644 resources/master_data/계수_건설품셈_기계설비5장.json create mode 100644 resources/master_data/계수_건설품셈_기계설비6장.json create mode 100644 resources/master_data/소요량_건설품셈_기계설비5장.json create mode 100644 resources/master_data/소요량_건설품셈_기계설비6장.json diff --git a/resources/master_data/계수_건설품셈_기계설비5장.json b/resources/master_data/계수_건설품셈_기계설비5장.json new file mode 100644 index 00000000..444473a1 --- /dev/null +++ b/resources/master_data/계수_건설품셈_기계설비5장.json @@ -0,0 +1,138 @@ +{ + "그룹": "계수", + "원문": "건설품셈", + "판": "2026", + "표": [ + { + "열쇠": "5-1-1 계수", + "이름": "일반밸브 및 콕류 설치 계수", + "기준": "인력품", + "출처": "건설품셈 기계설비 5-1-1", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "기계경비율", + "값": 2 + } + ], + "주": [ + "② 공구손료 및 경장비(전기드릴 등)의 기계경비는 인력품의 2%로 계상한다." + ] + }, + { + "열쇠": "5-1-2 계수", + "이름": "감압밸브장치 설치 계수", + "기준": "", + "출처": "건설품셈 기계설비 5-1-2", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "밸런스 파이프 필요 시 가산율", + "값": 30 + }, + { + "항목": "기계경비율", + "값": 2 + } + ], + "주": [ + "비고: - 밸런스 파이프를 필요로 할 경우에는 30% 가산한다.", + "④ 공구손료 및 경장비(전기드릴 등)의 기계경비는 인력품의 2%로 계상한다." + ] + }, + { + "열쇠": "5-2-1 계수", + "이름": "스팀트랩 장치 설치 계수", + "기준": "인력품", + "출처": "건설품셈 기계설비 5-2-1", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "기계경비율", + "값": 2 + } + ], + "주": [ + "⑤ 공구손료 및 경장비(전기드릴 등)의 기계경비는 인력품의 2%로 계상한다." + ] + }, + { + "열쇠": "5-3-1 계수", + "이름": "익스팬션조인트 설치 계수", + "기준": "인력품", + "출처": "건설품셈 기계설비 5-3-1", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "기계경비율", + "값": 2 + } + ], + "주": [ + "③ 공구손료 및 경장비(용접기 등)의 기계경비는 인력품의 2%로 계상하다." + ] + }, + { + "열쇠": "5-3-2 계수", + "이름": "플랙시블커넥터 설치 계수", + "기준": "인력품", + "출처": "건설품셈 기계설비 5-3-2", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "기계경비율", + "값": 2 + } + ], + "주": [ + "④ 공구손료 및 경장비(용접기 등)의 기계경비는 인력품의 2%로 계상하다." + ] + }, + { + "열쇠": "5-4-1 계수", + "이름": "수격방지기 설치 계수", + "기준": "인력품", + "출처": "건설품셈 기계설비 5-4-1", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "기계경비율", + "값": 2 + } + ], + "주": [ + "④ 공구손료 및 경장비(전기드릴 등)의 기계경비는 인력품의 2%로 계상한다." + ] + } + ] +} diff --git a/resources/master_data/계수_건설품셈_기계설비6장.json b/resources/master_data/계수_건설품셈_기계설비6장.json new file mode 100644 index 00000000..f147e316 --- /dev/null +++ b/resources/master_data/계수_건설품셈_기계설비6장.json @@ -0,0 +1,142 @@ +{ + "그룹": "계수", + "원문": "건설품셈", + "판": "2026", + "표": [ + { + "열쇠": "6-1-1 계수", + "이름": "유량계(직독식) 설치 계수", + "기준": "", + "출처": "건설품셈 기계설비 6-1-1", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "연속작업 불가 등 가산율", + "값": 20 + }, + { + "항목": "수도미터 · 온수미터 병행 설치 가산율", + "값": 30 + }, + { + "항목": "기계경비율", + "값": 2 + } + ], + "주": [ + "비고: - 건축물내의 유량계 설치위치・형태가 개소별로 상이하거나 연속작업이 불가능한 경우는 본 품의 20%를 가산한다.\n- 동일장소에서 수도미터, 온수미터를 병행 설치 시에는 단독 설치품에 30%를 가산한다.", + "③ 공구손료 및 경장비의 기계경비는 인력품의 2%로 계상한다." + ] + }, + { + "열쇠": "6-1-2 계수", + "이름": "유량계(원격식) 설치 계수", + "기준": "인력품", + "출처": "건설품셈 기계설비 6-1-2", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "기계경비율", + "값": 2 + } + ], + "주": [ + "⑤ 공구손료 및 경장비의 기계경비는 인력품의 2%로 계상한다." + ] + }, + { + "열쇠": "6-1-3 계수", + "이름": "세대용 계량기함 설치 계수", + "기준": "인력품", + "출처": "건설품셈 기계설비 6-1-3", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "기계경비율", + "값": 2 + } + ], + "주": [ + "④ 공구손료 및 경장비의 기계경비(드릴 등)는 인력품의 2%로 계상한다." + ] + }, + { + "열쇠": "6-2-1 계수", + "이름": "세대용 적산열량계 설치 계수", + "기준": "인력품", + "출처": "건설품셈 기계설비 6-2-1", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "기계경비율", + "값": 2 + } + ], + "주": [ + "⑤ 공구손료 및 경장비의 기계경비는 인력품의 2%로 계상한다." + ] + }, + { + "열쇠": "6-2-2 계수", + "이름": "건물용 적산열량계 설치 계수", + "기준": "인력품", + "출처": "건설품셈 기계설비 6-2-2", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "기계경비율", + "값": 2 + } + ], + "주": [ + "⑤ 공구손료 및 경장비의 기계경비는 인력품의 2%로 계상한다." + ] + }, + { + "열쇠": "6-2-3 계수", + "이름": "산업용 적산열량계 설치 계수", + "기준": "인력품", + "출처": "건설품셈 기계설비 6-2-3", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "기계경비율", + "값": 2 + } + ], + "주": [ + "⑤ 공구손료 및 경장비의 기계경비는 인력품의 2%로 계상한다." + ] + } + ] +} diff --git a/resources/master_data/소요량_건설품셈_기계설비5장.json b/resources/master_data/소요량_건설품셈_기계설비5장.json new file mode 100644 index 00000000..c622b4c9 --- /dev/null +++ b/resources/master_data/소요량_건설품셈_기계설비5장.json @@ -0,0 +1,664 @@ +{ + "그룹": "소요량", + "원문": "건설품셈", + "판": "2026", + "표": [ + { + "열쇠": "5-1-1 일반밸브 및 콕류 설치", + "이름": "일반밸브 및 콕류 설치", + "기준": "개당", + "출처": "건설품셈 기계설비 5-1-1", + "조건": { + "규격(㎜)": "범위" + }, + "값칸": { + "배관공": "인", + "보통인부": "인" + }, + "범위규칙": "규격(㎜): 이상·이하", + "줄": [ + { + "규격(㎜)": [ + 15, + 25 + ], + "배관공": 0.050 + }, + { + "규격(㎜)": [ + 32, + 50 + ], + "배관공": 0.074 + }, + { + "규격(㎜)": [ + 65, + 65 + ], + "배관공": 0.108, + "보통인부": 0.073 + }, + { + "규격(㎜)": [ + 80, + 80 + ], + "배관공": 0.141, + "보통인부": 0.083 + }, + { + "규격(㎜)": [ + 100, + 100 + ], + "배관공": 0.214, + "보통인부": 0.105 + }, + { + "규격(㎜)": [ + 125, + 125 + ], + "배관공": 0.278, + "보통인부": 0.121 + }, + { + "규격(㎜)": [ + 150, + 150 + ], + "배관공": 0.343, + "보통인부": 0.147 + }, + { + "규격(㎜)": [ + 200, + 200 + ], + "배관공": 0.471, + "보통인부": 0.188 + }, + { + "규격(㎜)": [ + 250, + 250 + ], + "배관공": 0.616, + "보통인부": 0.230 + }, + { + "규격(㎜)": [ + 300, + 300 + ], + "배관공": 0.788, + "보통인부": 0.261 + } + ], + "주": [ + "① 본 품은 설치위치 선정, 설치, 작동시험 및 마무리 작업을 포함한다.", + "② 공구손료 및 경장비(전기드릴 등)의 기계경비는 인력품의 2%로 계상한다." + ] + }, + { + "열쇠": "5-1-2 감압밸브장치 설치", + "이름": "감압밸브장치 설치", + "기준": "조당", + "출처": "건설품셈 기계설비 5-1-2", + "조건": { + "규격(㎜)": "범위" + }, + "값칸": { + "배관공": "인", + "보통인부": "인" + }, + "범위규칙": "규격(㎜): 이상·이하", + "줄": [ + { + "규격(㎜)": [ + 15, + 15 + ], + "배관공": 2.084, + "보통인부": 0.212 + }, + { + "규격(㎜)": [ + 20, + 20 + ], + "배관공": 2.527, + "보통인부": 0.295 + }, + { + "규격(㎜)": [ + 25, + 25 + ], + "배관공": 2.934, + "보통인부": 0.379 + }, + { + "규격(㎜)": [ + 32, + 32 + ], + "배관공": 3.462, + "보통인부": 0.496 + }, + { + "규격(㎜)": [ + 40, + 40 + ], + "배관공": 4.020, + "보통인부": 0.629 + }, + { + "규격(㎜)": [ + 50, + 50 + ], + "배관공": 4.668, + "보통인부": 0.796 + }, + { + "규격(㎜)": [ + 65, + 65 + ], + "배관공": 5.477, + "보통인부": 1.047 + }, + { + "규격(㎜)": [ + 80, + 80 + ], + "배관공": 6.224, + "보통인부": 1.297 + }, + { + "규격(㎜)": [ + 100, + 100 + ], + "배관공": 7.220, + "보통인부": 1.631 + }, + { + "규격(㎜)": [ + 125, + 125 + ], + "배관공": 8.465, + "보통인부": 2.049 + }, + { + "규격(㎜)": [ + 150, + 150 + ], + "배관공": 9.710, + "보통인부": 2.466 + }, + { + "규격(㎜)": [ + 200, + 200 + ], + "배관공": 11.815, + "보통인부": 3.301 + } + ], + "주": [ + "비고: - 밸런스 파이프를 필요로 할 경우에는 30% 가산한다.", + "① 본 품은 밸런스 파이프를 필요로 하지 않는 기준이다.", + "② 감압밸브, 게이트밸브, 글로브밸브, 스트레이너, 압력계, 안전밸브 등 바이패스 배관조립 및 설치, 배관시험을 포함한다.", + "③ 온도조절장치의 경우 본 품을 준용하여 적용할 수 있다.", + "④ 공구손료 및 경장비(전기드릴 등)의 기계경비는 인력품의 2%로 계상한다." + ] + }, + { + "열쇠": "5-2-1 스팀트랩 장치 설치", + "이름": "스팀트랩 장치 설치", + "기준": "조당", + "출처": "건설품셈 기계설비 5-2-1", + "조건": { + "규격(㎜)": "수" + }, + "값칸": { + "배관공": "인", + "보통인부": "인" + }, + "줄": [ + { + "규격(㎜)": 15, + "배관공": 0.632, + "보통인부": 0.235 + }, + { + "규격(㎜)": 20, + "배관공": 0.856, + "보통인부": 0.319 + }, + { + "규격(㎜)": 25, + "배관공": 1.081, + "보통인부": 0.402 + }, + { + "규격(㎜)": 32, + "배관공": 1.396, + "보통인부": 0.519 + }, + { + "규격(㎜)": 40, + "배관공": 1.756, + "보통인부": 0.653 + }, + { + "규격(㎜)": 50, + "배관공": 2.206, + "보통인부": 0.820 + } + ], + "주": [ + "① 본 품은 고압버킷 및 저압벨로스형 트랩을 포함한 기준이다.", + "② 트랩, 게이트밸브, 글로브밸브, 스트레이너, 바이패스 배관조립 및 설치, 배관시험을 포함한다.", + "③ 바이패스 구간에 기타 부속품이 추가되는 경우에는 별도 계상한다.", + "④ 스팀트랩 장치 설치를 위한 지지대 및 가대설치는 별도 계상한다.", + "⑤ 공구손료 및 경장비(전기드릴 등)의 기계경비는 인력품의 2%로 계상한다." + ] + }, + { + "열쇠": "5-3-1 익스팬션조인트 설치", + "이름": "익스팬션조인트 설치", + "기준": "개당", + "출처": "건설품셈 기계설비 5-3-1", + "조건": { + "규격(㎜)": "범위", + "구분": "고르기" + }, + "값칸": { + "배관공": "인", + "보통인부": "인" + }, + "범위규칙": "규격(㎜): 이상·이하", + "줄": [ + { + "규격(㎜)": [ + 20, + 25 + ], + "구분": "복식", + "배관공": 0.219, + "보통인부": 0.142 + }, + { + "규격(㎜)": [ + 20, + 25 + ], + "구분": "단식", + "배관공": 0.195, + "보통인부": 0.122 + }, + { + "규격(㎜)": [ + 32, + 32 + ], + "구분": "복식", + "배관공": 0.344, + "보통인부": 0.198 + }, + { + "규격(㎜)": [ + 32, + 32 + ], + "구분": "단식", + "배관공": 0.306, + "보통인부": 0.169 + }, + { + "규격(㎜)": [ + 40, + 40 + ], + "구분": "복식", + "배관공": 0.459, + "보통인부": 0.244 + }, + { + "규격(㎜)": [ + 40, + 40 + ], + "구분": "단식", + "배관공": 0.408, + "보통인부": 0.209 + }, + { + "규격(㎜)": [ + 50, + 50 + ], + "구분": "복식", + "배관공": 0.611, + "보통인부": 0.301 + }, + { + "규격(㎜)": [ + 50, + 50 + ], + "구분": "단식", + "배관공": 0.544, + "보통인부": 0.258 + }, + { + "규격(㎜)": [ + 65, + 65 + ], + "구분": "복식", + "배관공": 0.857, + "보통인부": 0.385 + }, + { + "규격(㎜)": [ + 65, + 65 + ], + "구분": "단식", + "배관공": 0.762, + "보통인부": 0.330 + }, + { + "규격(㎜)": [ + 80, + 80 + ], + "구분": "복식", + "배관공": 1.119, + "보통인부": 0.468 + }, + { + "규격(㎜)": [ + 80, + 80 + ], + "구분": "단식", + "배관공": 0.995, + "보통인부": 0.401 + }, + { + "규격(㎜)": [ + 100, + 100 + ], + "구분": "복식", + "배관공": 1.490, + "보통인부": 0.577 + }, + { + "규격(㎜)": [ + 100, + 100 + ], + "구분": "단식", + "배관공": 1.325, + "보통인부": 0.494 + }, + { + "규격(㎜)": [ + 125, + 125 + ], + "구분": "복식", + "배관공": 1.985, + "보통인부": 0.711 + }, + { + "규격(㎜)": [ + 125, + 125 + ], + "구분": "단식", + "배관공": 1.766, + "보통인부": 0.609 + }, + { + "규격(㎜)": [ + 150, + 150 + ], + "구분": "복식", + "배관공": 2.510, + "보통인부": 0.844 + }, + { + "규격(㎜)": [ + 150, + 150 + ], + "구분": "단식", + "배관공": 2.232, + "보통인부": 0.723 + }, + { + "규격(㎜)": [ + 200, + 200 + ], + "구분": "복식", + "배관공": 3.633, + "보통인부": 1.107 + }, + { + "규격(㎜)": [ + 200, + 200 + ], + "구분": "단식", + "배관공": 3.231, + "보통인부": 0.948 + } + ], + "주": [ + "① 본 품은 자재 및 공구 설치위치 재단, 플랜지 접합(강관) 또는 동관용접, 벽체 앵커 설치, 고정바 취부, 수압시험, 고정바 및 고정핀 제거, 정리 및 마무리 작업을 포함한다.", + "② 지지대 설치가 필요한 경우 별도 계상한다.", + "③ 공구손료 및 경장비(용접기 등)의 기계경비는 인력품의 2%로 계상하다." + ] + }, + { + "열쇠": "5-3-2 플랙시블커넥터 설치", + "이름": "플랙시블커넥터 설치", + "기준": "개당", + "출처": "건설품셈 기계설비 5-3-2", + "조건": { + "규격(㎜)": "범위" + }, + "값칸": { + "배관공": "인", + "보통인부": "인" + }, + "범위규칙": "규격(㎜): 이상·이하", + "줄": [ + { + "규격(㎜)": [ + 15, + 25 + ], + "배관공": 0.034, + "보통인부": 0.025 + }, + { + "규격(㎜)": [ + 32, + 50 + ], + "배관공": 0.083, + "보통인부": 0.046 + }, + { + "규격(㎜)": [ + 65, + 65 + ], + "배관공": 0.191, + "보통인부": 0.095 + }, + { + "규격(㎜)": [ + 80, + 80 + ], + "배관공": 0.260, + "보통인부": 0.114 + }, + { + "규격(㎜)": [ + 100, + 100 + ], + "배관공": 0.400, + "보통인부": 0.151 + }, + { + "규격(㎜)": [ + 125, + 125 + ], + "배관공": 0.560, + "보통인부": 0.193 + }, + { + "규격(㎜)": [ + 150, + 150 + ], + "배관공": 0.696, + "보통인부": 0.237 + }, + { + "규격(㎜)": [ + 200, + 200 + ], + "배관공": 0.968, + "보통인부": 0.315 + }, + { + "규격(㎜)": [ + 250, + 250 + ], + "배관공": 1.250, + "보통인부": 0.393 + }, + { + "규격(㎜)": [ + 300, + 300 + ], + "배관공": 1.512, + "보통인부": 0.461 + } + ], + "주": [ + "① 본 품은 진동을 흡수하는 플랙시블커넥터(커넥팅로드\\_플랜지접합형)를 설치하는 기준이다.", + "② 수평보기, 콘트롤로드설치, 배관시험을 포함한다.", + "③ 플랙시블조인트의 경우 본 품을 준용하여 적용할 수 있다.", + "④ 공구손료 및 경장비(용접기 등)의 기계경비는 인력품의 2%로 계상하다." + ] + }, + { + "열쇠": "5-4-1 수격방지기 설치", + "이름": "수격방지기 설치", + "기준": "개당", + "출처": "건설품셈 기계설비 5-4-1", + "조건": { + "규격(㎜)": "범위" + }, + "값칸": { + "배관공": "인", + "보통인부": "인" + }, + "범위규칙": "규격(㎜): 이상·이하", + "줄": [ + { + "규격(㎜)": [ + 15, + 25 + ], + "배관공": 0.028 + }, + { + "규격(㎜)": [ + 32, + 50 + ], + "배관공": 0.056 + }, + { + "규격(㎜)": [ + 65, + 65 + ], + "배관공": 0.073, + "보통인부": 0.024 + }, + { + "규격(㎜)": [ + 80, + 80 + ], + "배관공": 0.100, + "보통인부": 0.033 + }, + { + "규격(㎜)": [ + 100, + 100 + ], + "배관공": 0.136, + "보통인부": 0.045 + }, + { + "규격(㎜)": [ + 125, + 125 + ], + "배관공": 0.181, + "보통인부": 0.060 + }, + { + "규격(㎜)": [ + 150, + 150 + ], + "배관공": 0.226, + "보통인부": 0.075 + }, + { + "규격(㎜)": [ + 200, + 200 + ], + "배관공": 0.316, + "보통인부": 0.105 + } + ], + "주": [ + "① 본 품은 나사(삽입)접합식(50mm이하)과 플랜지접합식(65mm이상)의 설치 기준이다.", + "② 설치위치 선정, 수격방지기 설치, 작동시험 및 마무리 작업을 포함한다.", + "③ 수격방지기를 설치하기 위하여 벽체 홈파내기가 필요한 경우 별도 계상한다.", + "④ 공구손료 및 경장비(전기드릴 등)의 기계경비는 인력품의 2%로 계상한다." + ] + } + ] +} diff --git a/resources/master_data/소요량_건설품셈_기계설비6장.json b/resources/master_data/소요량_건설품셈_기계설비6장.json new file mode 100644 index 00000000..cfd69780 --- /dev/null +++ b/resources/master_data/소요량_건설품셈_기계설비6장.json @@ -0,0 +1,336 @@ +{ + "그룹": "소요량", + "원문": "건설품셈", + "판": "2026", + "표": [ + { + "열쇠": "6-1-1 유량계(직독식) 설치", + "이름": "유량계(직독식) 설치", + "기준": "개당", + "출처": "건설품셈 기계설비 6-1-1", + "조건": { + "규격(mm)": "범위", + "구분": "고르기" + }, + "값칸": { + "배관공": "인", + "보통인부": "인" + }, + "범위규칙": "규격(mm): 이상·이하", + "줄": [ + { + "규격(mm)": [ + 13, + 15 + ], + "구분": "보호통", + "배관공": 0.148, + "보통인부": 0.148 + }, + { + "규격(mm)": [ + 13, + 15 + ], + "구분": "유량계", + "배관공": 0.094, + "보통인부": 0.094 + }, + { + "규격(mm)": [ + 20, + 32 + ], + "구분": "보호통", + "배관공": 0.188, + "보통인부": 0.188 + }, + { + "규격(mm)": [ + 20, + 32 + ], + "구분": "유량계", + "배관공": 0.113, + "보통인부": 0.113 + }, + { + "규격(mm)": [ + 40, + 50 + ], + "구분": "보호통", + "배관공": 0.253, + "보통인부": 0.253 + }, + { + "규격(mm)": [ + 40, + 50 + ], + "구분": "유량계", + "배관공": 0.143, + "보통인부": 0.143 + }, + { + "규격(mm)": [ + 65, + 80 + ], + "구분": "유량계", + "배관공": 0.446, + "보통인부": 0.446 + }, + { + "규격(mm)": [ + 100, + 125 + ], + "구분": "유량계", + "배관공": 0.533, + "보통인부": 0.533 + }, + { + "규격(mm)": [ + 150, + 200 + ], + "구분": "유량계", + "배관공": 0.686, + "보통인부": 0.686 + }, + { + "규격(mm)": [ + 250, + 300 + ], + "구분": "유량계", + "배관공": 0.838, + "보통인부": 0.838 + } + ], + "주": [ + "비고: - 건축물내의 유량계 설치위치・형태가 개소별로 상이하거나 연속작업이 불가능한 경우는 본 품의 20%를 가산한다.\n- 동일장소에서 수도미터, 온수미터를 병행 설치 시에는 단독 설치품에 30%를 가산한다.", + "① 본 품은 수도미터(급수용), 온수미터(급탕용, 난방용)의 옥내배관 설치 기준이다.", + "② 가배관 철거, 유량계설치, 작동시험 및 마무리 작업을 포함한다.", + "③ 공구손료 및 경장비의 기계경비는 인력품의 2%로 계상한다." + ] + }, + { + "열쇠": "6-1-2 유량계(원격식) 설치", + "이름": "유량계(원격식) 설치", + "기준": "개당", + "출처": "건설품셈 기계설비 6-1-2", + "조건": { + "규격(mm)": "범위" + }, + "값칸": { + "배관공": "인", + "보통인부": "인" + }, + "범위규칙": "규격(mm): 이상·이하", + "줄": [ + { + "규격(mm)": [ + 13, + 15 + ], + "배관공": 0.112, + "보통인부": 0.112 + }, + { + "규격(mm)": [ + 20, + 32 + ], + "배관공": 0.132, + "보통인부": 0.132 + } + ], + "주": [ + "① 본 품은 원격식 냉수용 수도미터, 원격식 온수미터의 옥내배관 설치 기준이다.", + "② 가배관 철거, 유량계 설치, 전선관 결선, 시험・점검을 포함한다.", + "③ 밸브, 스트레이너 및 주위배관 설치는 별도 계상한다.", + "④ 전선관 배관 및 입선, 지시부 설치는 별도 계상한다.", + "⑤ 공구손료 및 경장비의 기계경비는 인력품의 2%로 계상한다." + ] + }, + { + "열쇠": "6-1-3 세대용 계량기함 설치", + "이름": "세대용 계량기함 설치", + "기준": "개소당", + "출처": "건설품셈 기계설비 6-1-3", + "조건": {}, + "값칸": { + "배관공": "인", + "보통인부": "인" + }, + "줄": [ + { + "배관공": 0.086, + "보통인부": 0.086 + } + ], + "주": [ + "① 본 품은 유량계(ø32mm이하) 보호를 위한 거치대 계량기함(2단 이하)의 설치 기준이다.", + "② 본 품은 앵커 구멍뚫기, 지지대 및 보호통 설치 작업을 포함한다.", + "③ 연결배관 및 밸브, 계량기 설치 작업은 별도 계상한다.", + "④ 공구손료 및 경장비의 기계경비(드릴 등)는 인력품의 2%로 계상한다." + ] + }, + { + "열쇠": "6-2-1 세대용 적산열량계 설치", + "이름": "세대용 적산열량계 설치", + "기준": "개당", + "출처": "건설품셈 기계설비 6-2-1", + "조건": { + "규격(mm)": "범위" + }, + "값칸": { + "배관공": "인", + "보통인부": "인" + }, + "범위규칙": "규격(mm): 이상·이하", + "줄": [ + { + "규격(mm)": [ + 13, + 15 + ], + "배관공": 0.122, + "보통인부": 0.122 + }, + { + "규격(mm)": [ + 20, + 32 + ], + "배관공": 0.142, + "보통인부": 0.142 + } + ], + "주": [ + "① 본 품은 세대 옥내배관에 적산열량계를 설치하는 기준이다.", + "② 본 품은 가배관 철거, 적산열량계 및 감온부 설치, 전선관 결선, 시험・점검을 포함한다.", + "③ 밸브, 스트레이너 및 주위배관 설치 품은 별도 계상한다.", + "④ 전선관 배관 및 입선, 지시부 설치는 별도 계상한다.", + "⑤ 공구손료 및 경장비의 기계경비는 인력품의 2%로 계상한다." + ] + }, + { + "열쇠": "6-2-2 건물용 적산열량계 설치", + "이름": "건물용 적산열량계 설치", + "기준": "개당", + "출처": "건설품셈 기계설비 6-2-2", + "조건": { + "규격(mm)": "범위" + }, + "값칸": { + "배관공": "인", + "보통인부": "인" + }, + "범위규칙": "규격(mm): 이상·이하", + "줄": [ + { + "규격(mm)": [ + 50, + 50 + ], + "배관공": 0.415, + "보통인부": 0.415 + }, + { + "규격(mm)": [ + 65, + 80 + ], + "배관공": 0.476, + "보통인부": 0.476 + }, + { + "규격(mm)": [ + 100, + 125 + ], + "배관공": 0.569, + "보통인부": 0.569 + }, + { + "규격(mm)": [ + 150, + 150 + ], + "배관공": 0.727, + "보통인부": 0.727 + } + ], + "주": [ + "① 본 품은 옥내배관에 적산열량계를 설치하는 기준이다.", + "② 본 품은 가배관 철거, 적산열량계 및 온도감지기 설치, 배선 결선, 시험·점검 작업을 포함한다.", + "③ 밸브, 스트레이너 및 주위배관 설치 품은 별도 계상한다.", + "④ 전선관 배관 및 입선, 지시부 설치는 별도 계상한다.", + "⑤ 공구손료 및 경장비의 기계경비는 인력품의 2%로 계상한다." + ] + }, + { + "열쇠": "6-2-3 산업용 적산열량계 설치", + "이름": "산업용 적산열량계 설치", + "기준": "대당", + "출처": "건설품셈 기계설비 6-2-3", + "조건": { + "규격(mm)": "범위" + }, + "값칸": { + "플랜트배관공": "인", + "특별인부": "인", + "계장공": "인" + }, + "범위규칙": "규격(mm): 이상·이하", + "줄": [ + { + "규격(mm)": [ + 32, + 32 + ], + "플랜트배관공": 0.71, + "특별인부": 0.71, + "계장공": 0.71 + }, + { + "규격(mm)": [ + 50, + 50 + ], + "플랜트배관공": 0.75, + "특별인부": 0.75, + "계장공": 0.75 + }, + { + "규격(mm)": [ + 100, + 100 + ], + "플랜트배관공": 0.85, + "특별인부": 0.85, + "계장공": 0.85 + }, + { + "규격(mm)": [ + 150, + 150 + ], + "플랜트배관공": 0.95, + "특별인부": 0.95, + "계장공": 0.95 + } + ], + "주": [ + "① 본 품은 발전소 등 집단에너지의 생산·수송·분배 또는 사용을 위한 시설에 산업용으로 적산열량계를 설치하는 기준이다", + "② 본 품은 가배관 철거, 배관세정작업, 유량계, 온도감지기, 열량지시계, 단자함 설치, 전기배선 및 결선, 시험을 포함한다.", + "③ 전선관, 밸브, 스트레이너 설치품은 별도 계상한다.", + "④ 열량지시계는 노출기준이며 매립 시는 별도 계상한다.", + "⑤ 공구손료 및 경장비의 기계경비는 인력품의 2%로 계상한다." + ] + } + ] +}