From 9a5d69361f3ff2bbe90923d17f2160b73e67544f Mon Sep 17 00:00:00 2001 From: umsangdon Date: Sat, 19 Sep 2026 17:48:32 +0900 Subject: [PATCH] =?UTF-8?q?knowledge(=EA=B1=B4=EC=84=A4=ED=92=88=EC=85=88?= =?UTF-8?q?=EA=B1=B4=EC=B6=951=EC=9E=A5):=20=EC=B2=A0=EA=B3=A8=EA=B3=B5?= =?UTF-8?q?=EC=82=AC=20=EC=86=8C=EC=9A=94=EB=9F=89=20=C2=B7=20=EA=B3=84?= =?UTF-8?q?=EC=88=98=20=EC=9A=94=EC=86=8C=ED=99=94?= MIME-Version: 1.0 Content-Type: text/plain; charset=UTF-8 Content-Transfer-Encoding: 8bit Co-Authored-By: Claude Sonnet 5 Claude-Session: https://claude.ai/code/session_016WRFJmmhPi4exAzHgPZHMT --- .../master_data/계수_건설품셈_건축1장.json | 1355 +++++++++++++++++ .../master_data/소요량_건설품셈_건축1장.json | 1070 +++++++++++++ 2 files changed, 2425 insertions(+) create mode 100644 resources/master_data/계수_건설품셈_건축1장.json create mode 100644 resources/master_data/소요량_건설품셈_건축1장.json diff --git a/resources/master_data/계수_건설품셈_건축1장.json b/resources/master_data/계수_건설품셈_건축1장.json new file mode 100644 index 00000000..66c90e19 --- /dev/null +++ b/resources/master_data/계수_건설품셈_건축1장.json @@ -0,0 +1,1355 @@ +{ + "그룹": "계수", + "원문": "건설품셈", + "판": "2026", + "표": [ + { + "열쇠": "1-1-1 계수", + "이름": "기본철골공수 계수", + "기준": "기본철골공수", + "출처": "건설품셈 건축 1-1-1", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "배·%" + }, + "줄": [ + { + "항목": "H형강부재(Rolled shape) 제작 시 기본철골공수 곱", + "값": 0.71, + "단위": "배" + }, + { + "항목": "공장제작 제경비(기본철골공수의)", + "값": 60, + "단위": "%" + } + ], + "주": [ + "비고: - 전용접부재(Built up) 제작을 기준으로 한 공수로써 H형강부재 (Rolled shape) 제작의\n경우는 기본 철골공수×0.71로 산정한다.", + "② 공장제작에 따른 제경비는 기본철골공수의 60%이며, 기본철골공수에 포함되지 않았다." + ] + }, + { + "열쇠": "1-1-2 작업난이도", + "이름": "작업난이도", + "기준": "기본철골공수에 곱", + "출처": "건설품셈 건축 1-1-2", + "조건": { + "구조공별": "고르기" + }, + "값칸": { + "난이도": "배" + }, + "줄": [ + { + "구조공별": "조립공장, 창고 등으로 가공부재종류가 적은 구조", + "난이도": [ + 0.8, + 0.95 + ] + }, + { + "구조공별": "사무청사 등 표준라멘구조", + "난이도": 1.0 + }, + { + "구조공별": "기타 가공부재 종류가 많은 구조", + "난이도": [ + 1.05, + 1.2 + ] + } + ], + "주": [ + "철골공수=기본철골공수×작업난이도" + ] + }, + { + "열쇠": "1-1-3 계수", + "이름": "기본용접공수 계수", + "기준": "기본용접공수", + "출처": "건설품셈 건축 1-1-3", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "배·%" + }, + "줄": [ + { + "항목": "H형강부재(Rolled shape) 제작 시 기본용접공수 곱", + "값": 0.73, + "단위": "배" + }, + { + "항목": "공장제작 제경비(기본용접공수의)", + "값": 60, + "단위": "%" + } + ], + "주": [ + "비고: - 전용접부재(Built up) 제작을 기준으로 한 공수로써 H형강부재 (Rolled shape) 제작의\n경우는 기본용접공수× 0.73으로 산정한다.", + "① 1ton당 필릿 용접 각장 6㎜ 환산수량이다.", + "② 공장제작에 따른 제경비는 기본용접공수의 60%이며, 기본용접공수에 포함되지 않았다.", + "④ 환산용접길이는 ‘용접길이×환산계수'로 산출한다." + ] + }, + { + "열쇠": "1-1-3 필릿용접 환산계수", + "이름": "필릿용접시의 환산계수", + "기준": "판두께별", + "출처": "건설품셈 건축 1-1-3", + "조건": { + "판두께(㎜)": "수" + }, + "값칸": { + "환산계수": "배" + }, + "줄": [ + { + "판두께(㎜)": 5, + "환산계수": 0.55 + }, + { + "판두께(㎜)": 6, + "환산계수": 0.68 + }, + { + "판두께(㎜)": 7, + "환산계수": 0.81 + }, + { + "판두께(㎜)": 8, + "환산계수": 0.94 + }, + { + "판두께(㎜)": 9, + "환산계수": 1.06 + }, + { + "판두께(㎜)": 10, + "환산계수": 1.17 + }, + { + "판두께(㎜)": 11, + "환산계수": 1.29 + }, + { + "판두께(㎜)": 12, + "환산계수": 1.40 + }, + { + "판두께(㎜)": 13, + "환산계수": 1.50 + }, + { + "판두께(㎜)": 14, + "환산계수": 1.60 + }, + { + "판두께(㎜)": 15, + "환산계수": 1.70 + }, + { + "판두께(㎜)": 16, + "환산계수": 1.79 + }, + { + "판두께(㎜)": 17, + "환산계수": 1.87 + }, + { + "판두께(㎜)": 18, + "환산계수": 2.0 + }, + { + "판두께(㎜)": 19, + "환산계수": 2.04 + }, + { + "판두께(㎜)": 20, + "환산계수": 2.11 + } + ], + "주": [] + }, + { + "열쇠": "1-1-3 V·K·X용접 환산계수", + "이름": "V, K, X용접시의 환산계수", + "기준": "판두께별", + "출처": "건설품셈 건축 1-1-3", + "조건": { + "판두께(㎜)": "수" + }, + "값칸": { + "환산계수": "배" + }, + "줄": [ + { + "판두께(㎜)": 6, + "환산계수": 2.86 + }, + { + "판두께(㎜)": 7, + "환산계수": 2.94 + }, + { + "판두께(㎜)": 8, + "환산계수": 3.03 + }, + { + "판두께(㎜)": 9, + "환산계수": 3.12 + }, + { + "판두께(㎜)": 10, + "환산계수": 3.22 + }, + { + "판두께(㎜)": 11, + "환산계수": 3.32 + }, + { + "판두께(㎜)": 12, + "환산계수": 3.43 + }, + { + "판두께(㎜)": 13, + "환산계수": 3.54 + }, + { + "판두께(㎜)": 14, + "환산계수": 3.66 + }, + { + "판두께(㎜)": 15, + "환산계수": 3.78 + }, + { + "판두께(㎜)": 16, + "환산계수": 3.90 + }, + { + "판두께(㎜)": 18, + "환산계수": 4.17 + }, + { + "판두께(㎜)": 20, + "환산계수": 4.45 + }, + { + "판두께(㎜)": 22, + "환산계수": 4.75 + }, + { + "판두께(㎜)": 24, + "환산계수": 5.07 + }, + { + "판두께(㎜)": 26, + "환산계수": 5.41 + }, + { + "판두께(㎜)": 28, + "환산계수": 5.77 + }, + { + "판두께(㎜)": 30, + "환산계수": 6.14 + }, + { + "판두께(㎜)": 32, + "환산계수": 6.53 + }, + { + "판두께(㎜)": 34, + "환산계수": 6.95 + }, + { + "판두께(㎜)": 35, + "환산계수": 7.16 + }, + { + "판두께(㎜)": 40, + "환산계수": 8.29 + }, + { + "판두께(㎜)": 45, + "환산계수": 9.54 + }, + { + "판두께(㎜)": 50, + "환산계수": 10.90 + }, + { + "판두께(㎜)": 55, + "환산계수": 12.58 + }, + { + "판두께(㎜)": 60, + "환산계수": 13.97 + }, + { + "판두께(㎜)": 65, + "환산계수": 15.68 + }, + { + "판두께(㎜)": 70, + "환산계수": 17.50 + }, + { + "판두께(㎜)": 75, + "환산계수": 19.44 + }, + { + "판두께(㎜)": 80, + "환산계수": 21.49 + } + ], + "주": [] + }, + { + "열쇠": "1-1-4 강재총사용량 보정계수", + "이름": "강재총사용량에 의한 보정계수", + "기준": "기본용접공수에 곱", + "출처": "건설품셈 건축 1-1-4", + "조건": { + "강재총사용량(t)": "범위" + }, + "값칸": { + "보정계수": "배" + }, + "범위규칙": "이상·미만", + "줄": [ + { + "강재총사용량(t)": [ + null, + 30 + ], + "보정계수": 1.36 + }, + { + "강재총사용량(t)": [ + 30, + 60 + ], + "보정계수": 1.31 + }, + { + "강재총사용량(t)": [ + 60, + 100 + ], + "보정계수": 1.22 + }, + { + "강재총사용량(t)": [ + 100, + 200 + ], + "보정계수": 1.16 + }, + { + "강재총사용량(t)": [ + 200, + 300 + ], + "보정계수": 1.08 + }, + { + "강재총사용량(t)": [ + 300, + 400 + ], + "보정계수": 1.04 + }, + { + "강재총사용량(t)": [ + 400, + 500 + ], + "보정계수": 1.01 + }, + { + "강재총사용량(t)": [ + 500, + 600 + ], + "보정계수": 0.99 + }, + { + "강재총사용량(t)": [ + 600, + 700 + ], + "보정계수": 0.97 + }, + { + "강재총사용량(t)": [ + 700, + 800 + ], + "보정계수": 0.96 + }, + { + "강재총사용량(t)": [ + 800, + 900 + ], + "보정계수": 0.94 + }, + { + "강재총사용량(t)": [ + 900, + 1000 + ], + "보정계수": 0.93 + }, + { + "강재총사용량(t)": [ + 1000, + 1500 + ], + "보정계수": 0.92 + }, + { + "강재총사용량(t)": [ + 1500, + 2000 + ], + "보정계수": 0.89 + }, + { + "강재총사용량(t)": [ + 2000, + null + ], + "보정계수": 0.86 + } + ], + "주": [ + "용접공수=기본용접공수×강재총사용량에 의한 보정계수" + ] + }, + { + "열쇠": "1-2-1 계수", + "이름": "현장 세우기 계수", + "기준": "본 품", + "출처": "건설품셈 건축 1-2-1", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "자재 진출입 어렵고 작업공간 협소한 현장 할증율", + "값": 20 + } + ], + "주": [ + "④ 자재의 진출입이 어렵고, 작업공간이 협소한 현장(도심지 등)에서는 본 품의 20%를 할증하여 적용 한다." + ] + }, + { + "열쇠": "1-2-1 표a-1 ㎡당 강재사용량 보정치(6층 미만)", + "이름": "㎡당 강재사용에 따른 보정치(6층 미만인 경우)", + "기준": "1㎡당", + "출처": "건설품셈 건축 1-2-1", + "조건": { + "강재사용량(㎏/㎡)": "범위" + }, + "값칸": { + "보정치(a)": "배" + }, + "범위규칙": "이상·미만", + "줄": [ + { + "강재사용량(㎏/㎡)": [ + null, + 50 + ], + "보정치(a)": 1.3 + }, + { + "강재사용량(㎏/㎡)": [ + 50, + 55 + ], + "보정치(a)": 1.26 + }, + { + "강재사용량(㎏/㎡)": [ + 55, + 60 + ], + "보정치(a)": 1.22 + }, + { + "강재사용량(㎏/㎡)": [ + 60, + 65 + ], + "보정치(a)": 1.18 + }, + { + "강재사용량(㎏/㎡)": [ + 65, + 70 + ], + "보정치(a)": 1.14 + }, + { + "강재사용량(㎏/㎡)": [ + 70, + 80 + ], + "보정치(a)": 1.1 + }, + { + "강재사용량(㎏/㎡)": [ + 80, + 90 + ], + "보정치(a)": 1.05 + }, + { + "강재사용량(㎏/㎡)": [ + 90, + 110 + ], + "보정치(a)": 1.0 + }, + { + "강재사용량(㎏/㎡)": [ + 110, + 130 + ], + "보정치(a)": 0.95 + }, + { + "강재사용량(㎏/㎡)": [ + 130, + 150 + ], + "보정치(a)": 0.89 + }, + { + "강재사용량(㎏/㎡)": [ + 150, + 190 + ], + "보정치(a)": 0.84 + }, + { + "강재사용량(㎏/㎡)": [ + 190, + 250 + ], + "보정치(a)": 0.77 + } + ], + "주": [] + }, + { + "열쇠": "1-2-1 표a-2 ㎡당 강재사용량 보정치(6층 이상)", + "이름": "㎡당 강재사용에 따른 보정치(6층 이상인 경우)", + "기준": "1㎡당", + "출처": "건설품셈 건축 1-2-1", + "조건": { + "N(㎏/㎡)": "수" + }, + "값칸": { + "보정치(a)": "배" + }, + "줄": [ + { + "N(㎏/㎡)": 40, + "보정치(a)": 1.06 + }, + { + "N(㎏/㎡)": 50, + "보정치(a)": 1.03 + }, + { + "N(㎏/㎡)": 60, + "보정치(a)": 1.00 + }, + { + "N(㎏/㎡)": 70, + "보정치(a)": 0.97 + }, + { + "N(㎏/㎡)": 80, + "보정치(a)": 0.94 + }, + { + "N(㎏/㎡)": 90, + "보정치(a)": 0.91 + }, + { + "N(㎏/㎡)": 100, + "보정치(a)": 0.88 + }, + { + "N(㎏/㎡)": 110, + "보정치(a)": 0.85 + }, + { + "N(㎏/㎡)": 120, + "보정치(a)": 0.82 + }, + { + "N(㎏/㎡)": 130, + "보정치(a)": 0.79 + } + ], + "주": [ + "a=1+(60-N)×0.003, N : ㎡당 강재사용량(㎏/㎡)" + ] + }, + { + "열쇠": "1-2-1 표b-1 강재총사용량 보정치(6층 미만)", + "이름": "강재 총 사용량에 따른 보정치(6층 미만인 경우)", + "기준": "", + "출처": "건설품셈 건축 1-2-1", + "조건": { + "강재총사용량(ton)": "범위" + }, + "값칸": { + "보정치(b)": "배" + }, + "범위규칙": "이상·미만", + "줄": [ + { + "강재총사용량(ton)": [ + null, + 10 + ], + "보정치(b)": 1.34 + }, + { + "강재총사용량(ton)": [ + 10, + 15 + ], + "보정치(b)": 1.3 + }, + { + "강재총사용량(ton)": [ + 15, + 20 + ], + "보정치(b)": 1.26 + }, + { + "강재총사용량(ton)": [ + 20, + 30 + ], + "보정치(b)": 1.22 + }, + { + "강재총사용량(ton)": [ + 30, + 50 + ], + "보정치(b)": 1.18 + }, + { + "강재총사용량(ton)": [ + 50, + 80 + ], + "보정치(b)": 1.14 + }, + { + "강재총사용량(ton)": [ + 80, + 150 + ], + "보정치(b)": 1.1 + }, + { + "강재총사용량(ton)": [ + 150, + 250 + ], + "보정치(b)": 1.05 + }, + { + "강재총사용량(ton)": [ + 250, + 500 + ], + "보정치(b)": 1.0 + }, + { + "강재총사용량(ton)": [ + 500, + 1000 + ], + "보정치(b)": 0.95 + }, + { + "강재총사용량(ton)": [ + 1000, + null + ], + "보정치(b)": 0.89 + } + ], + "주": [] + }, + { + "열쇠": "1-2-1 표b-2 강재총사용량 보정치(6층 이상)", + "이름": "강재 총 사용량에 따른 보정치(6층 이상인 경우)", + "기준": "", + "출처": "건설품셈 건축 1-2-1", + "조건": { + "T(ton)": "범위" + }, + "값칸": { + "보정치(b)": "배" + }, + "범위규칙": "이상·이하", + "줄": [ + { + "T(ton)": [ + null, + 40 + ], + "보정치(b)": 1.3 + }, + { + "T(ton)": [ + 50, + 50 + ], + "보정치(b)": 1.26 + }, + { + "T(ton)": [ + 60, + 60 + ], + "보정치(b)": 1.24 + }, + { + "T(ton)": [ + 70, + 70 + ], + "보정치(b)": 1.22 + }, + { + "T(ton)": [ + 80, + 80 + ], + "보정치(b)": 1.21 + }, + { + "T(ton)": [ + 90, + 90 + ], + "보정치(b)": 1.20 + }, + { + "T(ton)": [ + 100, + 100 + ], + "보정치(b)": 1.19 + }, + { + "T(ton)": [ + 200, + 200 + ], + "보정치(b)": 1.045 + }, + { + "T(ton)": [ + 300, + 300 + ], + "보정치(b)": 1.02 + }, + { + "T(ton)": [ + 400, + 400 + ], + "보정치(b)": 1.008 + }, + { + "T(ton)": [ + 500, + 500 + ], + "보정치(b)": 1.00 + }, + { + "T(ton)": [ + 600, + 600 + ], + "보정치(b)": 0.995 + }, + { + "T(ton)": [ + 700, + 700 + ], + "보정치(b)": 0.991 + }, + { + "T(ton)": [ + 800, + 800 + ], + "보정치(b)": 0.989 + }, + { + "T(ton)": [ + 900, + 900 + ], + "보정치(b)": 0.987 + }, + { + "T(ton)": [ + 1000, + 1000 + ], + "보정치(b)": 0.985 + }, + { + "T(ton)": [ + 1100, + 1100 + ], + "보정치(b)": 0.984 + }, + { + "T(ton)": [ + 1200, + 1200 + ], + "보정치(b)": 0.983 + }, + { + "T(ton)": [ + 1300, + 1300 + ], + "보정치(b)": 0.982 + }, + { + "T(ton)": [ + 1400, + 1400 + ], + "보정치(b)": 0.981 + } + ], + "주": [ + "100ton이하 b=1.12+7/T, 100ton이상 b=0.97+15/T\nT : 가공총톤수(ton)" + ] + }, + { + "열쇠": "1-2-1 표c 건물높이 보정치(6층 이상)", + "이름": "건물 높이에 따른 보정치(6층 이상인 경우)", + "기준": "", + "출처": "건설품셈 건축 1-2-1", + "조건": { + "건물높이 H(m)": "수" + }, + "값칸": { + "보정치(c)": "배" + }, + "줄": [ + { + "건물높이 H(m)": 50, + "보정치(c)": 1.045 + }, + { + "건물높이 H(m)": 45, + "보정치(c)": 1.038 + }, + { + "건물높이 H(m)": 40, + "보정치(c)": 1.030 + }, + { + "건물높이 H(m)": 35, + "보정치(c)": 1.023 + }, + { + "건물높이 H(m)": 30, + "보정치(c)": 1.015 + }, + { + "건물높이 H(m)": 25, + "보정치(c)": 1.008 + }, + { + "건물높이 H(m)": 20, + "보정치(c)": 1.000 + }, + { + "건물높이 H(m)": 15, + "보정치(c)": 0.993 + }, + { + "건물높이 H(m)": 10, + "보정치(c)": 0.985 + }, + { + "건물높이 H(m)": 5, + "보정치(c)": 0.978 + } + ], + "주": [ + "c=1+(0.5H-10)×0.003, H : 건물높이" + ] + }, + { + "열쇠": "1-2-1 표d 스판평균면적 보정치(6층 이상)", + "이름": "스판평균면적에 따른 보정치(6층 이상인 경우)", + "기준": "", + "출처": "건설품셈 건축 1-2-1", + "조건": { + "스판평균면적 S(㎡)": "수" + }, + "값칸": { + "구간": "㎡", + "보정치(d)": "배" + }, + "줄": [ + { + "스판평균면적 S(㎡)": 20, + "구간": [ + 16, + 25 + ], + "보정치(d)": 1.98 + }, + { + "스판평균면적 S(㎡)": 30, + "구간": [ + 26, + 35 + ], + "보정치(d)": 1.43 + }, + { + "스판평균면적 S(㎡)": 40, + "구간": [ + 36, + 45 + ], + "보정치(d)": 1.16 + }, + { + "스판평균면적 S(㎡)": 50, + "구간": [ + 46, + 55 + ], + "보정치(d)": 0.99 + }, + { + "스판평균면적 S(㎡)": 60, + "구간": [ + 56, + 65 + ], + "보정치(d)": 0.88 + }, + { + "스판평균면적 S(㎡)": 70, + "구간": [ + 66, + 75 + ], + "보정치(d)": 0.80 + }, + { + "스판평균면적 S(㎡)": 80, + "구간": [ + 76, + 85 + ], + "보정치(d)": 0.74 + } + ], + "주": [ + "d=33/S+0.33, S : 스판 평균면적(㎡)", + "※ 본 표는 간사이(Span)가 10m 이하인 경우임" + ] + }, + { + "열쇠": "1-2-2 계수", + "이름": "탑다운공법 지하 현장 세우기 계수", + "기준": "인력품", + "출처": "건설품셈 건축 1-2-2", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "공구손료 및 경장비 기계경비율", + "값": 2 + } + ], + "주": [ + "④ 공구손료 및 경장비(전기드릴, 용접기 등)의 기계경비는 인력품의 2%로 계상한다." + ] + }, + { + "열쇠": "1-2-4 계수", + "이름": "고장력 볼트 본조임 계수", + "기준": "인력품", + "출처": "건설품셈 건축 1-2-4", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "공구손료 및 경장비 기계경비율", + "값": 3 + } + ], + "주": [ + "③ 공구손료 및 경장비(전기드릴 등)의 기계경비는 인력품의 3%로 계상한다." + ] + }, + { + "열쇠": "1-2-4 고장력 볼트조임 보정계수", + "이름": "고장력 볼트조임 보정계수표(a)", + "기준": "1ton당 볼트본수 · 강재총사용량별 표준단가에 곱", + "출처": "건설품셈 건축 1-2-4", + "조건": { + "강재총사용량(t)": "범위", + "1t당 볼트본수(본)": "범위" + }, + "값칸": { + "보정계수 a": "배" + }, + "범위규칙": "이상·미만", + "줄": [ + { + "강재총사용량(t)": [ + 300, + 500 + ], + "1t당 볼트본수(본)": [ + null, + 50 + ], + "보정계수 a": 0.91 + }, + { + "강재총사용량(t)": [ + 300, + 500 + ], + "1t당 볼트본수(본)": [ + 50, + 90 + ], + "보정계수 a": 0.92 + }, + { + "강재총사용량(t)": [ + 300, + 500 + ], + "1t당 볼트본수(본)": [ + 90, + null + ], + "보정계수 a": 0.93 + }, + { + "강재총사용량(t)": [ + 500, + 1000 + ], + "1t당 볼트본수(본)": [ + null, + 50 + ], + "보정계수 a": 0.87 + }, + { + "강재총사용량(t)": [ + 500, + 1000 + ], + "1t당 볼트본수(본)": [ + 50, + 90 + ], + "보정계수 a": 0.88 + }, + { + "강재총사용량(t)": [ + 500, + 1000 + ], + "1t당 볼트본수(본)": [ + 90, + null + ], + "보정계수 a": 0.89 + }, + { + "강재총사용량(t)": [ + 1000, + null + ], + "1t당 볼트본수(본)": [ + null, + 50 + ], + "보정계수 a": 0.84 + }, + { + "강재총사용량(t)": [ + 1000, + null + ], + "1t당 볼트본수(본)": [ + 50, + 90 + ], + "보정계수 a": 0.85 + }, + { + "강재총사용량(t)": [ + 1000, + null + ], + "1t당 볼트본수(본)": [ + 90, + null + ], + "보정계수 a": 0.86 + } + ], + "주": [ + "④ 본 품은 철골설계수량 300ton 미만을 표준으로 한 것이며 300ton 이상인 고장력 볼트 본조임은 다음의 보정치를 적용한다.", + "※ 볼트본조임비=표준단가×K\n보정계수 K=a(고장력 볼트조임 보정계수)" + ] + }, + { + "열쇠": "1-2-5 계수", + "이름": "현장용접 계수", + "기준": "인력품", + "출처": "건설품셈 건축 1-2-5", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "공구손료 및 경장비 기계경비율", + "값": 4 + } + ], + "주": [ + "③ 공구손료 및 경장비(용접기 등)의 기계경비는 인력품의 4%로 계상한다." + ] + }, + { + "열쇠": "1-2-6 계수", + "이름": "앵커 볼트 설치 계수", + "기준": "인력품", + "출처": "건설품셈 건축 1-2-6", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "공구손료 및 경장비 기계경비율", + "값": 2 + }, + { + "항목": "콘크리트 독립주 위 등 비계 불량 장소 가산율(까지)", + "값": 20 + } + ], + "주": [ + "⑤ 공구손료 및 경장비(용접기 등)의 기계경비는 인력품의 2%로 계상한다.", + "⑥ 콘크리트 독립주 위에서나 기타 비계가 양호치 못한 장소에서는 본 품의 20%까지 가산한다." + ] + }, + { + "열쇠": "1-2-7 계수", + "이름": "장비의 가설 및 해체이동 계수", + "기준": "인력품", + "출처": "건설품셈 건축 1-2-7", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "타워크레인 가설이동 해체 공구손료", + "값": 3 + } + ], + "주": [ + "④ 타워크레인의 가설이동 해체에 소요되는 공구손료는 인력품의 3%로 계상한다." + ] + }, + { + "열쇠": "1-3-2 계수", + "이름": "데크플레이트 플라즈마 절단 계수", + "기준": "인력품", + "출처": "건설품셈 건축 1-3-2", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "공구손료 및 경장비 기계경비율", + "값": 10 + } + ], + "주": [ + "③ 공구손료 및 경장비(플라즈마 절단기 등)의 기계경비는 인력품의 10%로 계상한다." + ] + }, + { + "열쇠": "1-3-3 계수", + "이름": "데크플레이트 설치 계수", + "기준": "인력품", + "출처": "건설품셈 건축 1-3-3", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "공구손료 및 경장비 기계경비율", + "값": 5 + }, + { + "항목": "11층에서 15층까지 인력품 할증율", + "값": 4 + }, + { + "항목": "16층 이상 매 5개층 증가마다 추가 가산율", + "값": 1 + } + ], + "주": [ + "비고: - 본 품은 10층까지 적용하며, 높이별 인력품의 할증은 11층에서 15층까지는\n4%, 16층 이상은 매 5개층 증가마다 1%씩 추가 가산한다.", + "④ 공구손료 및 경장비(용접기 등)의 기계경비는 인력품의 5%로 계상한다." + ] + }, + { + "열쇠": "1-4-2 계수", + "이름": "스터드볼트 설치 계수", + "기준": "인력품", + "출처": "건설품셈 건축 1-4-2", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "공구손료 및 경장비 기계경비율 자동용접", + "값": 22 + }, + { + "항목": "공구손료 및 경장비 기계경비율 수동용접", + "값": 18 + }, + { + "항목": "잡재료(주재료비의)", + "값": 5 + } + ], + "주": [ + "⑤ 공구손료 및 경장비(용접기 등)는 자동용접인 경우 인력품의 22%, 수동용접인 경우 인력품의 18%로 계상한다.", + "⑥ 잡재료는 주재료비의 5%로 계상한다." + ] + }, + { + "열쇠": "1-4-3 계수", + "이름": "철골 내화 피복뿜칠 계수", + "기준": "인력품", + "출처": "건설품셈 건축 1-4-3", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "공구손료 및 경장비 기계경비율", + "값": 5 + } + ], + "주": [ + "⑤ 공구손료 및 경장비(분사기 등)의 기계경비는 인력품의 5%로 계상한다." + ] + }, + { + "열쇠": "1-4-4 계수", + "이름": "경량형강철골조 조립설치 계수", + "기준": "인력품", + "출처": "건설품셈 건축 1-4-4", + "조건": { + "항목": "고르기" + }, + "값칸": { + "값": "%" + }, + "줄": [ + { + "항목": "공구손료", + "값": 3 + }, + { + "항목": "부자재(스크류, 힐티 등) 주자재비의", + "값": 3 + } + ], + "주": [ + "⑤ 공구손료는 인력품의 3%로 계상한다.", + "⑧ 주재료(스터드, 트랙, 조이스트 등)는 설계수량에 따라 계상하며, 부자재(스크류, 힐티 등)는 주자재비의 3%로 계상한다." + ] + } + ] +} diff --git a/resources/master_data/소요량_건설품셈_건축1장.json b/resources/master_data/소요량_건설품셈_건축1장.json new file mode 100644 index 00000000..53fb71b0 --- /dev/null +++ b/resources/master_data/소요량_건설품셈_건축1장.json @@ -0,0 +1,1070 @@ +{ + "그룹": "소요량", + "원문": "건설품셈", + "판": "2026", + "표": [ + { + "열쇠": "1-1-1 기본철골공수", + "이름": "기본철골공수", + "기준": "1t", + "출처": "건설품셈 건축 1-1-1", + "조건": { + "강재총사용량(t)": "범위" + }, + "값칸": { + "기본철골공수": "인·일/t" + }, + "범위규칙": "이상·미만", + "줄": [ + { + "강재총사용량(t)": [ + null, + 60 + ], + "기본철골공수": 2.48 + }, + { + "강재총사용량(t)": [ + 60, + 100 + ], + "기본철골공수": 2.31 + }, + { + "강재총사용량(t)": [ + 100, + 300 + ], + "기본철골공수": 2.20 + }, + { + "강재총사용량(t)": [ + 300, + 1000 + ], + "기본철골공수": 1.97 + }, + { + "강재총사용량(t)": [ + 1000, + 2000 + ], + "기본철골공수": 1.75 + }, + { + "강재총사용량(t)": [ + 2000, + null + ], + "기본철골공수": 1.63 + } + ], + "주": [ + "비고: - 전용접부재(Built up) 제작을 기준으로 한 공수로써 H형강부재 (Rolled shape) 제작의\n경우는 기본 철골공수×0.71로 산정한다.", + "① 기본철골공수에는 비계 및 보조공이 포함되었다.", + "② 공장제작에 따른 제경비는 기본철골공수의 60%이며, 기본철골공수에 포함되지 않았다.", + "③ 산재보험료・기타경비・간접노무비・일반관리비・이윤 등은 공장제작에 따른 제경비에 포함되지 않았다.", + "④ 용접품은 별도 계상한다." + ] + }, + { + "열쇠": "1-1-2 소요 부자재량", + "이름": "소요 부자재량", + "기준": "ton당", + "출처": "건설품셈 건축 1-1-2", + "조건": { + "재료": "고르기" + }, + "값칸": { + "전용접부재": "㎥·㎏·본", + "H형강부재": "㎥·㎏·본" + }, + "줄": [ + { + "재료": "산소", + "단위": "㎥", + "전용접부재": 7.0, + "H형강부재": 3.5 + }, + { + "재료": "L.P.G", + "단위": "㎏", + "전용접부재": 2.8, + "H형강부재": 1.4 + }, + { + "재료": "서비스볼트", + "단위": "본", + "전용접부재": 2.0, + "H형강부재": 1.0 + }, + { + "재료": "보조강재", + "단위": "㎏", + "전용접부재": 6.0, + "H형강부재": 2.0 + } + ], + "주": [ + "※ 철골제작에서 용접을 제외한 철골가공 조립과정에서 소요되는 부자재량이며, 현장 철골 세우기는 별도 계상함.", + "※ 서비스 볼트는 일반 볼트이며 규격은 설계에 따라 계상함." + ] + }, + { + "열쇠": "1-1-3 기본용접공수", + "이름": "기본용접공수", + "기준": "1t", + "출처": "건설품셈 건축 1-1-3", + "조건": { + "환산용접길이(m/t)": "범위" + }, + "값칸": { + "기본용접공수": "인·일/t" + }, + "범위규칙": "이상·미만", + "줄": [ + { + "환산용접길이(m/t)": [ + null, + 20 + ], + "기본용접공수": 0.22 + }, + { + "환산용접길이(m/t)": [ + 20, + 30 + ], + "기본용접공수": 0.37 + }, + { + "환산용접길이(m/t)": [ + 30, + 40 + ], + "기본용접공수": 0.51 + }, + { + "환산용접길이(m/t)": [ + 40, + 50 + ], + "기본용접공수": 0.63 + }, + { + "환산용접길이(m/t)": [ + 50, + 60 + ], + "기본용접공수": 0.73 + }, + { + "환산용접길이(m/t)": [ + 60, + 70 + ], + "기본용접공수": 0.85 + }, + { + "환산용접길이(m/t)": [ + 70, + 80 + ], + "기본용접공수": 0.95 + }, + { + "환산용접길이(m/t)": [ + 80, + 90 + ], + "기본용접공수": 1.05 + }, + { + "환산용접길이(m/t)": [ + 90, + 100 + ], + "기본용접공수": 1.15 + }, + { + "환산용접길이(m/t)": [ + 100, + null + ], + "기본용접공수": 1.24 + }, + { + "환산용접길이(m/t)": [ + 110, + 120 + ], + "기본용접공수": 1.34 + }, + { + "환산용접길이(m/t)": [ + 120, + 130 + ], + "기본용접공수": 1.43 + }, + { + "환산용접길이(m/t)": [ + 130, + 140 + ], + "기본용접공수": 1.51 + }, + { + "환산용접길이(m/t)": [ + 140, + 150 + ], + "기본용접공수": 1.60 + }, + { + "환산용접길이(m/t)": [ + 150, + 160 + ], + "기본용접공수": 1.69 + }, + { + "환산용접길이(m/t)": [ + 160, + 170 + ], + "기본용접공수": 1.77 + }, + { + "환산용접길이(m/t)": [ + 170, + 180 + ], + "기본용접공수": 1.85 + }, + { + "환산용접길이(m/t)": [ + 180, + 190 + ], + "기본용접공수": 1.93 + }, + { + "환산용접길이(m/t)": [ + 190, + 200 + ], + "기본용접공수": 2.02 + }, + { + "환산용접길이(m/t)": [ + 200, + null + ], + "기본용접공수": 2.09 + } + ], + "주": [ + "비고: - 전용접부재(Built up) 제작을 기준으로 한 공수로써 H형강부재 (Rolled shape) 제작의\n경우는 기본용접공수× 0.73으로 산정한다.", + "① 1ton당 필릿 용접 각장 6㎜ 환산수량이다.", + "② 공장제작에 따른 제경비는 기본용접공수의 60%이며, 기본용접공수에 포함되지 않았다.", + "③ 산재보험료・기타경비・간접노무비・일반관리비・이윤 등은 공장제작에 따른 제경비에 포함되지 않았다.", + "④ 환산용접길이는 ‘용접길이×환산계수'로 산출한다.", + "⑤ 특수 구조물의 경우, 세부적인 용접과 절단작업에 대하여, 기계설비부문 플랜트용접공사의 세부 항목을 참조할 수 있다." + ] + }, + { + "열쇠": "1-1-4 소요 용접재료량", + "이름": "소요 용접재료량", + "기준": "m당", + "출처": "건설품셈 건축 1-1-4", + "조건": { + "재료": "고르기" + }, + "값칸": { + "수용접": "㎏", + "반자동용접": "㎏", + "자동용접": "㎏" + }, + "줄": [ + { + "재료": "용접봉", + "단위": "㎏", + "수용접": 0.42 + }, + { + "재료": "CO_2 와이어", + "단위": "㎏", + "반자동용접": 0.23 + }, + { + "재료": "탄산가스", + "단위": "㎏", + "반자동용접": 0.12 + }, + { + "재료": "잠호용접와이어", + "단위": "㎏", + "자동용접": 0.21 + }, + { + "재료": "FLUX", + "단위": "㎏", + "자동용접": 0.21 + } + ], + "주": [ + "※ 필릿 용접 6㎜ 환산수량으로 반자동용접을 표준으로 함." + ] + }, + { + "열쇠": "1-2-1 현장 세우기", + "이름": "현장 세우기", + "기준": "ton당", + "출처": "건설품셈 건축 1-2-1", + "조건": { + "층수(층)": "범위" + }, + "값칸": { + "철골공": "인", + "비계공": "인", + "특별인부": "인" + }, + "범위규칙": "이상·미만", + "줄": [ + { + "층수(층)": [ + null, + 6 + ], + "철골공": 0.33, + "비계공": 0.14, + "특별인부": 0.07 + }, + { + "층수(층)": [ + 6, + 20 + ], + "철골공": 0.44, + "비계공": 0.18, + "특별인부": 0.09 + }, + { + "층수(층)": [ + 20, + 30 + ], + "철골공": 0.52, + "비계공": 0.22, + "특별인부": 0.11 + }, + { + "층수(층)": [ + 30, + 40 + ], + "철골공": 0.59, + "비계공": 0.24, + "특별인부": 0.12 + }, + { + "층수(층)": [ + 40, + null + ], + "철골공": 0.65, + "비계공": 0.27, + "특별인부": 0.14 + } + ], + "주": [ + "① 본 품은 가공이 완료된 상태의 철골을 현장에 설치하는 기준이다.", + "② 본 품은 철골 세우기, 가조임 및 변형잡기를 포함한다.", + "③ 타워크레인의 가설・이동・해체에 소요되는 품은 별도 계상한다.", + "④ 자재의 진출입이 어렵고, 작업공간이 협소한 현장(도심지 등)에서는 본 품의 20%를 할증하여 적용 한다.", + "⑤ 재료량은 다음을 참고하여 적용한다.", + "⑥ 현장세우기 보정", + "※ 현장조립비=표준단가×K1(보정계수 K1=a×b×c×d)\na. ㎡당강재사용량에 따른 보정치··························<표・a-1><표・a-2>\nb. 강재총사용량에 따른 보정치·····························<표・b-1><표・b-2>\nc. 건물 높이에 따른 보정치··································<표・c>\nd. 스판평균면적(割面積)에 따른 보정치················<표・d>", + "※ 발전소, 공항터미널 등과 같은 특수구조물과 50층 이상(또는 150M 이상)의 초고층건물 현장세우기는 별도 계상한다." + ] + }, + { + "열쇠": "1-2-1 보통볼트 재료량", + "이름": "현장 세우기 재료량", + "기준": "ton당", + "출처": "건설품셈 건축 1-2-1", + "조건": { + "구분": "고르기", + "규격": "고르기" + }, + "값칸": { + "수량": "본", + "비고": "글" + }, + "줄": [ + { + "구분": "보통볼트", + "규격": "가조임", + "단위": "본", + "수량": 20.0, + "비고": "손율 4%" + } + ], + "주": [] + }, + { + "열쇠": "1-2-2 탑다운공법 지하 현장 세우기", + "이름": "탑다운공법 지하 현장 세우기", + "기준": "ton당", + "출처": "건설품셈 건축 1-2-2", + "조건": { + "지하층수(층)": "범위" + }, + "값칸": { + "철골공": "인", + "용접공": "인", + "특별인부": "인" + }, + "범위규칙": "이상·미만", + "줄": [ + { + "지하층수(층)": [ + null, + 4 + ], + "철골공": 0.812, + "용접공": 0.382, + "특별인부": 0.171 + }, + { + "지하층수(층)": [ + 4, + 7 + ], + "철골공": 0.878, + "용접공": 0.344, + "특별인부": 0.208 + }, + { + "지하층수(층)": [ + 7, + 10 + ], + "철골공": 0.927, + "용접공": 0.306, + "특별인부": 0.242 + }, + { + "지하층수(층)": [ + 10, + null + ], + "철골공": 0.976, + "용접공": 0.268, + "특별인부": 0.276 + } + ], + "주": [ + "① 본 품은 탑다운 공법에 의해 설치되는 1층 바닥 스판을 포함하여 지하층 바닥 스판에 가공이 완료된 상태의 철골을 현장에서 설치하는 기준이다.", + "② 지하 현장 세우기는 철골 가공 조립(공장 생산)이 완료된 상태로 지하에 철골 자재 반입이 완료된 것을 조립 설치하는 기준으로 지상에서 지하로 자재를 반입하는 작업은 제외되어 있다.", + "③ 본 품은 철골 세우기, 가조임 및 변형잡기, 고장력 볼트 본조임, 현장용접을 포함한다.", + "④ 공구손료 및 경장비(전기드릴, 용접기 등)의 기계경비는 인력품의 2%로 계상한다.", + "⑤ 재료량은 설계수량을 적용한다." + ] + }, + { + "열쇠": "1-2-3 철골세우기 장비의 작업능력", + "이름": "철골세우기 장비의 작업능력", + "기준": "1일", + "출처": "건설품셈 건축 1-2-3", + "조건": { + "철골세우기중기": "고르기", + "철골건물의 종류": "고르기" + }, + "값칸": { + "1일 처리능력": "ton" + }, + "줄": [ + { + "철골세우기중기": "크레인 (무한궤도/타이어)", + "철골건물의 종류": "창고소규모건물, 공장대규모건물, 트러스, 거더류", + "1일 처리능력": 15 + }, + { + "철골세우기중기": "크레인 (무한궤도/타이어)", + "철골건물의 종류": "기둥, 크레인거더", + "1일 처리능력": 25 + }, + { + "철골세우기중기": "크레인 (무한궤도/타이어)", + "철골건물의 종류": "기타", + "1일 처리능력": 8 + }, + { + "철골세우기중기": "타워크레인", + "철골건물의 종류": "고층건물", + "1일 처리능력": 15 + }, + { + "철골세우기중기": "트럭탑재형 크레인", + "철골건물의 종류": "소규모건물", + "1일 처리능력": 10 + }, + { + "철골세우기중기": "굴착기", + "철골건물의 종류": "탑다운공법 지하 거더류", + "1일 처리능력": 12 + } + ], + "주": [ + "① 부재의 단위중량에 대한 작업량 및 작업여건에 따라 처리능력을 별도로 결정할 수 있다.", + "② 철골세우기 장비의 손료산정기준에 적용한다.", + "③ 장비규격은 작업여건(작업범위, 위치 등)에 따라 변경할 수 있다." + ] + }, + { + "열쇠": "1-2-4 고장력 볼트 본조임", + "이름": "고장력 볼트 본조임", + "기준": "강재 ton당", + "출처": "건설품셈 건축 1-2-4", + "조건": { + "1t당 볼트본수(본/t)": "범위" + }, + "값칸": { + "철골공": "인", + "특별인부": "인" + }, + "범위규칙": "이상·미만", + "줄": [ + { + "1t당 볼트본수(본/t)": [ + null, + 30 + ], + "철골공": 0.43, + "특별인부": 0.12 + }, + { + "1t당 볼트본수(본/t)": [ + 30, + 50 + ], + "철골공": 0.52, + "특별인부": 0.14 + }, + { + "1t당 볼트본수(본/t)": [ + 50, + 70 + ], + "철골공": 0.59, + "특별인부": 0.16 + }, + { + "1t당 볼트본수(본/t)": [ + 70, + 90 + ], + "철골공": 0.66, + "특별인부": 0.18 + }, + { + "1t당 볼트본수(본/t)": [ + 90, + 110 + ], + "철골공": 0.72, + "특별인부": 0.20 + }, + { + "1t당 볼트본수(본/t)": [ + 110, + null + ], + "철골공": 0.74, + "특별인부": 0.20 + } + ], + "주": [ + "① 본 품은 철골세우기 완료 후 볼트 조임을 완료하는 작업 기준이다.", + "② 본 품은 고장력 볼트(육각볼트, 토크-전단형볼트)의 본조임 및 조임검사가 포함된 것이다.", + "③ 공구손료 및 경장비(전기드릴 등)의 기계경비는 인력품의 3%로 계상한다.", + "④ 본 품은 철골설계수량 300ton 미만을 표준으로 한 것이며 300ton 이상인 고장력 볼트 본조임은 다음의 보정치를 적용한다.", + "※ 볼트본조임비=표준단가×K\n보정계수 K=a(고장력 볼트조임 보정계수)" + ] + }, + { + "열쇠": "1-2-5 현장용접", + "이름": "현장용접", + "기준": "각장 6㎜ 환산용접 길이 1m당", + "출처": "건설품셈 건축 1-2-5", + "조건": {}, + "값칸": { + "용접공": "인" + }, + "줄": [ + { + "용접공": 0.04 + } + ], + "주": [ + "① 본 품은 철골부재를 CO2 용접으로 반자동 용접하는 기준이다.", + "② 본 품은 용접 준비, 용접 및 정리작업이 포함된 것이다.", + "③ 공구손료 및 경장비(용접기 등)의 기계경비는 인력품의 4%로 계상한다.", + "④ 별도의 방풍설비가 필요한 경우 별도로 계상한다.", + "⑤ 본 품은 용접 준비, 용접 및 정리작업이 포함된 것이다.", + "⑥ 재료량은 다음을 참고하여 적용한다." + ] + }, + { + "열쇠": "1-2-5 현장용접 재료량", + "이름": "현장용접 재료량", + "기준": "각장 6㎜ 환산용접 길이 1m당", + "출처": "건설품셈 건축 1-2-5", + "조건": { + "구분": "고르기" + }, + "값칸": { + "수량": "" + }, + "줄": [ + { + "구분": "CO_2 와이어", + "단위": "㎏", + "수량": 0.28 + }, + { + "구분": "탄산가스", + "단위": "㎏", + "수량": 0.14 + } + ], + "주": [] + }, + { + "열쇠": "1-2-6 앵커 볼트 설치", + "이름": "앵커 볼트 설치", + "기준": "개당", + "출처": "건설품셈 건축 1-2-6", + "조건": { + "앵커볼트 규격(ø㎜ 이하)": "수" + }, + "값칸": { + "철골공": "인", + "특별인부": "인" + }, + "줄": [ + { + "앵커볼트 규격(ø㎜ 이하)": 16, + "철골공": 0.05, + "특별인부": 0.02 + }, + { + "앵커볼트 규격(ø㎜ 이하)": 20, + "철골공": 0.08, + "특별인부": 0.03 + }, + { + "앵커볼트 규격(ø㎜ 이하)": 24, + "철골공": 0.12, + "특별인부": 0.05 + }, + { + "앵커볼트 규격(ø㎜ 이하)": 28, + "철골공": 0.16, + "특별인부": 0.06 + }, + { + "앵커볼트 규격(ø㎜ 이하)": 32, + "철골공": 0.20, + "특별인부": 0.07 + }, + { + "앵커볼트 규격(ø㎜ 이하)": 40, + "철골공": 0.23, + "특별인부": 0.09 + } + ], + "주": [ + "① 본 품은 철골세우기를 위해 앵커볼트 설치를 기준한 것이다.", + "② 본 품은 설치위치 확인, 앵커볼트 및 틀 설치가 포함된 것이다.", + "③ 별도의 철제틀이 필요한 경우에는 철물 제작품을 적용한다.", + "④ 일반철골공사에 적용하고 기계설치에는 적용하지 않는다.", + "⑤ 공구손료 및 경장비(용접기 등)의 기계경비는 인력품의 2%로 계상한다.", + "⑥ 콘크리트 독립주 위에서나 기타 비계가 양호치 못한 장소에서는 본 품의 20%까지 가산한다." + ] + }, + { + "열쇠": "1-2-7 장비의 가설 및 해체이동", + "이름": "철골세우기용 장비의 가설 및 해체이동", + "기준": "대당", + "출처": "건설품셈 건축 1-2-7", + "조건": { + "기종": "고르기", + "공종별": "고르기" + }, + "값칸": { + "비계공": "인" + }, + "줄": [ + { + "기종": "타워크레인", + "공종별": "가설", + "비계공": 42.0 + }, + { + "기종": "타워크레인", + "공종별": "해체정비", + "비계공": 42.0 + }, + { + "기종": "타워크레인", + "공종별": "수직이동(1회당)", + "비계공": 6.0 + } + ], + "주": [ + "① 타워크레인 규격은 8ton(권상능력)×50m(작업반경)이고 가설높이는 32.5m일 때의 기준이다.", + "② 타워크레인의 가설이동 해체의 장비와 자재운반(부속자재포함)의 기계경비는 별도 계상한다.", + "③ 타워크레인의 기초설치 및 철거에 소요되는 재료 및 품은 별도 계상한다.", + "④ 타워크레인의 가설이동 해체에 소요되는 공구손료는 인력품의 3%로 계상한다.", + "⑤ 본 품의 타워크레인은 건물 외부 고정식일 경우이며 브레이싱 설치 해체에 대한 재료 및 품은 별도 계상한다.", + "⑥ 본 품의 타워크레인의 가설・해체정비, 수직 이동품은 특수 비계공이며 이외의 필요한 품(전공 등)은 별도 계상한다.", + "⑦ 타워크레인의 가설이동 해체 소요일수 표준은 다음과 같다." + ] + }, + { + "열쇠": "1-2-7 가설이동 해체 소요일수", + "이름": "타워크레인의 가설이동 해체 소요일수 표준", + "기준": "", + "출처": "건설품셈 건축 1-2-7", + "조건": { + "구분": "고르기" + }, + "값칸": { + "소요일수": "일" + }, + "줄": [ + { + "구분": "가설", + "소요일수": [ + 5, + 8 + ] + }, + { + "구분": "정비", + "소요일수": 1, + "소요일수원문": "100ton시마다 1일" + }, + { + "구분": "수직이동", + "소요일수": 1 + }, + { + "구분": "해체", + "소요일수": [ + 4, + 7 + ] + } + ], + "주": [] + }, + { + "열쇠": "1-3-1 데크플레이트 가스절단", + "이름": "데크플레이트 가스절단", + "기준": "절단길이 10m당", + "출처": "건설품셈 건축 1-3-1", + "조건": { + "판두께(㎜)": "수" + }, + "값칸": { + "용접공": "인" + }, + "줄": [ + { + "판두께(㎜)": 1.6, + "용접공": 0.17 + }, + { + "판두께(㎜)": 2.3, + "용접공": 0.23 + } + ], + "주": [ + "① 본 품에는 공구손료가 포함되어 있다.", + "② 재료량은 다음을 참고하여 적용한다." + ] + }, + { + "열쇠": "1-3-1 가스절단 재료량", + "이름": "데크플레이트 가스절단 재료량", + "기준": "절단길이 10m당", + "출처": "건설품셈 건축 1-3-1", + "조건": { + "판두께(㎜)": "수" + }, + "값칸": { + "산소": "㎥", + "아세틸렌": "㎏", + "L.P.G": "㎏" + }, + "줄": [ + { + "판두께(㎜)": 1.6, + "산소": 0.37, + "아세틸렌": 0.15, + "L.P.G": 0.12 + }, + { + "판두께(㎜)": 2.3, + "산소": 0.42, + "아세틸렌": 0.16, + "L.P.G": 0.14 + } + ], + "주": [ + "※ 아세틸렌(산소포함) 또는 L.P.G 중 한가지만 선택 사용한다.", + "※ 산소량은 대기압상태의 기준량이며, 압축산소는 35℃에서 150기압으로 압축용기에 넣어 사용하는 것을 기준으로 한다." + ] + }, + { + "열쇠": "1-3-2 데크플레이트 플라즈마 절단", + "이름": "데크플레이트 플라즈마 절단", + "기준": "절단길이 10m당", + "출처": "건설품셈 건축 1-3-2", + "조건": {}, + "값칸": { + "철골공": "인", + "특별인부": "인" + }, + "줄": [ + { + "철골공": 0.05, + "특별인부": 0.02 + } + ], + "주": [ + "① 본 품은 플라즈마 절단기를 사용하여 데크플레이트를 절단하는 기준으로 일반 데크플레이트와 철근일체형 데크플레이트에 동일하게 적용한다.", + "② 본 품은 절단위치 확인, 데크플레이트 절단작업이 포함된 것이다.", + "③ 공구손료 및 경장비(플라즈마 절단기 등)의 기계경비는 인력품의 10%로 계상한다." + ] + }, + { + "열쇠": "1-3-3 데크플레이트 설치", + "이름": "데크플레이트 설치", + "기준": "㎡당", + "출처": "건설품셈 건축 1-3-3", + "조건": {}, + "값칸": { + "철골공": "인", + "용접공": "인", + "특별인부": "인" + }, + "줄": [ + { + "철골공": 0.03, + "용접공": 0.01, + "특별인부": 0.01 + } + ], + "주": [ + "비고: - 본 품은 10층까지 적용하며, 높이별 인력품의 할증은 11층에서 15층까지는\n4%, 16층 이상은 매 5개층 증가마다 1%씩 추가 가산한다.", + "① 본 품은 주문 제작된 데크플레이트를 설치하는 기준으로 일반 데크플레이트와 철근 일체형 데크플레이트에 동일하게 적용한다.", + "② 본 품은 데크설치(판개), 고정 및 용접, 마감부 처리, 개구부 막이, 엔드플레이트, 콘크리트 스토퍼 작업이 포함된 것이다.", + "③ 소모재료는 설계에 따라 별도 계상한다.", + "④ 공구손료 및 경장비(용접기 등)의 기계경비는 인력품의 5%로 계상한다.", + "⑤ 사용재료의 양중은 현장여건에 따라 양중기계를 선정할 수 있으며 기계경비는 별도 계상한다." + ] + }, + { + "열쇠": "1-4-1 부대철골 설치", + "이름": "부대철골 설치", + "기준": "ton당", + "출처": "건설품셈 건축 1-4-1", + "조건": { + "구분": "고르기", + "규격": "고르기" + }, + "값칸": { + "수량": "" + }, + "줄": [ + { + "구분": "철골공", + "단위": "인", + "수량": 1.67 + }, + { + "구분": "특별인부", + "단위": "인", + "수량": 0.42 + }, + { + "구분": "크레인", + "규격": "50ton", + "단위": "hr", + "수량": 2.50 + } + ], + "주": [ + "① 본 품은 중도리, 띠장, 캐노피 등 철골공사와 병행하여 시공되는 부대철골의 설치를 기준한 것이다.", + "② 본 품은 현장설치 및 볼트조임 작업이 포함된 것이다.", + "③ 장비의 규격은 작업여건(작업범위, 위치 등)에 따라 변경할 수 있다." + ] + }, + { + "열쇠": "1-4-2 스터드볼트 설치", + "이름": "스터드볼트(Stud bolt) 설치", + "기준": "1,000개당", + "출처": "건설품셈 건축 1-4-2", + "조건": { + "대상": "고르기", + "용접방식": "고르기" + }, + "값칸": { + "용접공": "인", + "특별인부": "인" + }, + "줄": [ + { + "대상": "데크플레이트", + "용접방식": "자동용접", + "용접공": 1.52, + "특별인부": 0.90 + }, + { + "대상": "데크플레이트", + "용접방식": "수동용접", + "용접공": 2.67, + "특별인부": 1.58 + }, + { + "대상": "지하 철골 기둥", + "용접방식": "자동용접", + "용접공": 0.94, + "특별인부": 0.63 + }, + { + "대상": "지하 철골 기둥", + "용접방식": "수동용접", + "용접공": 1.65, + "특별인부": 1.11 + } + ], + "주": [ + "① 데크플레이트는 데크플레이트가 설치된 상태에서 스터드볼트를 2열로 용접하는 것을 기준으로 한다.", + "② 지하 철골 기둥은 탑다운공법에 의해 설치된 지하 철골 기둥에 스터드볼트를 용접하는 것을 기준으로 한다.", + "③ 자동용접은 스터드볼트 전용용접기를 사용하는 것을 말하며, 수동용접은 아크용접기를 사용하는 것을 말한다.", + "④ 본 품은 설치위치 확인, 용접 작업이 포함된 것이다.", + "⑤ 공구손료 및 경장비(용접기 등)는 자동용접인 경우 인력품의 22%, 수동용접인 경우 인력품의 18%로 계상한다.", + "⑥ 잡재료는 주재료비의 5%로 계상한다." + ] + }, + { + "열쇠": "1-4-3 철골 내화 피복뿜칠", + "이름": "철골 내화 피복뿜칠", + "기준": "㎜/100㎡당", + "출처": "건설품셈 건축 1-4-3", + "조건": { + "구분": "고르기", + "규격": "고르기" + }, + "값칸": { + "수량": "" + }, + "줄": [ + { + "구분": "도장공", + "단위": "인", + "수량": 0.062 + }, + { + "구분": "특별인부", + "단위": "인", + "수량": 0.056 + }, + { + "구분": "보통인부", + "단위": "인", + "수량": 0.062 + }, + { + "구분": "그라우팅믹서", + "규격": "390×2(ℓ)", + "단위": "hr", + "수량": 0.180 + }, + { + "구분": "그라우팅펌프", + "규격": "40∼125(ℓ/min)", + "단위": "hr", + "수량": 0.180 + } + ], + "주": [ + "① 본 품은 내화 피복 질석계 자재를 습식으로 시공하는 기준이다.", + "② 본 품은 방진막 설치 및 해체, 뿜칠작업이 포함된 것이다.", + "③ 철골 바탕면 처리, 청소 및 검사는 별도 계상한다.", + "④ 소모재료 및 장비의 설치, 해체, 이동에 소요되는 품은 별도 계상한다.", + "⑤ 공구손료 및 경장비(분사기 등)의 기계경비는 인력품의 5%로 계상한다.", + "⑥ 철골내화 피복 뿜칠 내화 시간은 국토교통부고시 내화구조의 성능기준에 따른다.", + "⑦ 재료량은 다음을 참고하여 적용한다." + ] + }, + { + "열쇠": "1-4-3 철골 내화 피복뿜칠 재료량", + "이름": "철골 내화 피복뿜칠 재료량", + "기준": "㎜/100㎡당", + "출처": "건설품셈 건축 1-4-3", + "조건": { + "구분": "고르기" + }, + "값칸": { + "수량": "" + }, + "줄": [ + { + "구분": "질석", + "단위": "㎏", + "수량": 38.8 + } + ], + "주": [] + }, + { + "열쇠": "1-4-4 경량형강철골조 조립설치", + "이름": "경량형강철골조 조립설치", + "기준": "ton당", + "출처": "건설품셈 건축 1-4-4", + "조건": { + "구조": "고르기" + }, + "값칸": { + "철공": "인" + }, + "줄": [ + { + "구조": "내력식", + "철공": 15.93 + }, + { + "구조": "비내력식", + "철공": 12.54 + } + ], + "주": [ + "① 본 품은 건축구조용 표면처리 경량형강을 기준한 것이다.", + "② 본 품은 경량형강 철골세우기로서 내력식은 4층이하를 기준한 것이다.", + "③ 지붕트러스는 내력식을 적용한다.", + "④ 본 품은 소운반, 먹매김, 가공, 조립・설치품이 포함되어 있다.", + "⑤ 공구손료는 인력품의 3%로 계상한다.", + "⑥ 경량형강 철골설치에 장비가 필요한 경우 기계경비는 별도 계상한다.", + "⑦ 외부 비계매기가 필요할 경우 별도 계상한다.", + "⑧ 주재료(스터드, 트랙, 조이스트 등)는 설계수량에 따라 계상하며, 부자재(스크류, 힐티 등)는 주자재비의 3%로 계상한다." + ] + } + ] +}