From aaa8eb5c8c04dd0c11dc4aa3af38475011a44366 Mon Sep 17 00:00:00 2001 From: umsangdon Date: Sat, 19 Sep 2026 03:25:30 +0900 Subject: [PATCH] =?UTF-8?q?knowledge(=ED=92=88=EC=85=88md):=20=EA=B1=B4?= =?UTF-8?q?=EC=84=A4=208-2=20=EA=B3=B5=EA=B8=B0=EC=A1=B0=ED=99=94=EA=B8=B0?= =?UTF-8?q?=20=EC=9E=91=EC=84=B1?= MIME-Version: 1.0 Content-Type: text/plain; charset=UTF-8 Content-Transfer-Encoding: 8bit --- .../8-02_공기조화기.md | 145 +++++++++++++++++- 1 file changed, 142 insertions(+), 3 deletions(-) diff --git a/resources/knowledge/original/원가계산/건설공사_표준품셈/본문/04_기계설비부문/제08장_공기조화설비공사/8-02_공기조화기.md b/resources/knowledge/original/원가계산/건설공사_표준품셈/본문/04_기계설비부문/제08장_공기조화설비공사/8-02_공기조화기.md index 76c42bb6..d35ed0b1 100644 --- a/resources/knowledge/original/원가계산/건설공사_표준품셈/본문/04_기계설비부문/제08장_공기조화설비공사/8-02_공기조화기.md +++ b/resources/knowledge/original/원가계산/건설공사_표준품셈/본문/04_기계설비부문/제08장_공기조화설비공사/8-02_공기조화기.md @@ -5,10 +5,149 @@ PDF쪽: 749~752 인쇄쪽: 693~696 시작표지: 8-2 공기조화기 끝표지: 8-3 보일러 및 방열기 -상태: 대기 -작성: +상태: 검증대기 +작성: sub_desktop_1 검증: 원천: 글자층 -기계검사: +기계검사: 통과 · ①수 결손 0 허구 0 · ②글자 빠짐 0 더함 0 확정지문: --- + +## 8-2 공기조화기 + +### 8-2-1 공기가열기, 공기냉각기, 공기여과기 설치 + +(대당) + +| 규격 | | 기계설비공(인) | 보통인부(인) | +|---|---|---|---| +| 유효길이 | 610㎜ | 2.0 | 0.60 | +| | 762〃 | 2.5 | 0.75 | +| | 914〃 | 3.0 | 0.90 | +| | 1,067〃 | 3.5 | 1.00 | +| | 1,219〃 | 4.0 | 1.20 | +| | 1,372〃 | 4.5 | 1.30 | +| | 1,524〃 | 5.0 | 1.50 | +| | 1,676〃 | 5.5 | 1.60 | +| | 1,829〃 | 6.0 | 1.80 | +| | 1,981〃 | 6.5 | 1.90 | +| | 2,134〃 | 7.0 | 2.10 | +| | 2,286〃 | 7.5 | 2.20 | +| | 2,438〃 | 8.0 | 2.40 | +| | 2,591〃 | 8.5 | 2.50 | +| | 2,875〃 | 10.0 | 3.00 | +| | 3,048〃 | 11.0 | 3.30 | + + + +[주] +① 직접 팽창식(디스트리뷰터 포함)은 본 품에 30%를 가산한다. +② 헤더 분리형은 본 품에 50%를 가산한다. +③ 연결 케이싱은 납땜 시공한다. +④ 풍압이 특히 높을 경우에는 별도 계상한다. +⑤ 에로핀, 플레이트핀 및 핀피치에 상관없이 핀치수 18본 1∼3열을 기준(W254㎜×H737㎜)한 것이다. +⑥ 튜브의 본 수에 의한 증감은 2본 감할 때마다 4%씩 감하고, 2본 증할 때마다 5%씩 가산한다. + +### 8-2-2 패키지형 공기조화기 설치 + +| 작업횟수 | | 1회 | | | | | | 2회 | | | | 1회 | | | | | | +|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| +| 층별
공종 | | 지하1층 | | 지하2층 | | 지하3층 | | 지하2층 | | 지하3층 | | 2층 | | 5층 | | 9층 | | +| 출력
(㎾) | 반입
대수 | 비계
공 | 특별
인부 | 비계
공 | 특별
인부 | 비계
공 | 특별
인부 | 비계
공 | 특별
인부 | 비계
공 | 특별
인부 | 비계
공 | 특별
인부 | 비계
공 | 특별
인부 | 비계
공 | 특별
인부 | +| 0.75이하 | 15대분 | 9.7 | 4.9 | 10.3 | 5.1 | 11.5 | 5.7 | 19.5 | 9.7 | 21.2 | 10.6 | 9.7 | 4.9 | 11.5 | 5.7 | 12.9 | 6.5 | +| 1.5 | 8 | 9.7 | 4.9 | 10.3 | 5.1 | 11.5 | 5.7 | 19.5 | 9.7 | 21.2 | 10.6 | 9.7 | 4.9 | 11.5 | 5.7 | 12.9 | 6.5 | +| 2.2 | 5 | 9.7 | 4.9 | 10.3 | 5.1 | 11.5 | 5.7 | 19.5 | 9.7 | 21.2 | 10.6 | 9.7 | 4.9 | 11.5 | 5.7 | 12.9 | 6.5 | +| 3.7 | 4 | 9.7 | 4.9 | 10.3 | 5.1 | 11.5 | 5.7 | 19.5 | 9.7 | 21.2 | 10.6 | 9.7 | 4.9 | 11.5 | 5.7 | 12.9 | 6.5 | +| 5.5 | 3 | 8.2 | 4.1 | 8.8 | 4.4 | 9.7 | 4.9 | 16.2 | 8.1 | 18.0 | 9.0 | 8.2 | 4.1 | 9.7 | 4.9 | 11.5 | 5.7 | +| 7.5 | 2 | 8.2 | 4.1 | 8.8 | 4.4 | 9.7 | 4.9 | 16.2 | 8.1 | 18.0 | 9.0 | 8.2 | 4.1 | 9.7 | 4.9 | 11.5 | 5.7 | +| 9.8 | 1 | 6.5 | 3.2 | 7.1 | 3.5 | 8.8 | 4.4 | 12.9 | 6.5 | 14.7 | 7.4 | 6.5 | 3.2 | 8.8 | 4.4 | 9.7 | 4.9 | +| 15.0 | 1 | 7.9 | 4.0 | 8.8 | 4.4 | 9.7 | 4.9 | 16.2 | 8.1 | 21.2 | 10.6 | 8.2 | 4.1 | 9.7 | 4.9 | 11.5 | 5.7 | +| 17.0 | 1 | 12.9 | 6.5 | 13.5 | 6.8 | 14.7 | 7.4 | 25.9 | 13.0 | 26.5 | 13.3 | 12.9 | 6.5 | 14.7 | 7.4 | 16.2 | 8.1 | +| 20.0 | 1 | 14.7 | 7.4 | 15.3 | 7.7 | 16.2 | 8.1 | 29.2 | 14.6 | 30.9 | 15.5 | 14.7 | 7.4 | 16.2 | 8.1 | 18.0 | 9.0 | +| 37.0 | 1 | 25.9 | 13.0 | 26.5 | 13.3 | 27.7 | 13.8 | 51.9 | 25.9 | 53.7 | 26.8 | 25.9 | 13.0 | 27.7 | 13.8 | 29.2 | 14.6 | + + + + +[주] +① 반입 및 설치품을 포함한 것이다. +② 반입시 사용되는 장비사용료를 포함한 것이다. + +### 8-2-3 공기조화기(Air Handling Unit) 설치 + +(대당) + +| 규격 | | 기계설비공(인) | 보통인부(인) | +|---|---|---|---| +| 1) 수냉식 패키지형 | | | | +| 압축기전동기출력 | 0.75㎾ 이하 | 0.5 | 0.5 | +| | 1.1㎾이하 | 0.6 | 0.6 | +| | 1.5㎾이하 | 1.0 | 1.0 | +| | 2.2㎾이하 | 1.3 | 1.3 | +| | 3.7㎾이하 | 1.5 | 1.5 | +| | 10.8㎾이하 | 2.0 | 2.0 | +| | 30.0㎾이하 | 3.0 | 3.0 | +| | 37.0㎾이하 | 3.5 | 3.5 | + +| 2) 공냉식 패키지형 | | | | +| 압축기전동기출력 | 2.2㎾이하 | 1.0 | 1.0 | +| | 3.7㎾이하 | 1.3 | 1.3 | +| | 7.5㎾이하 | 1.5 | 1.5 | +| 3) 핸들링유닛전동기출력 | 7.5㎾이하 | 4.0 | 1.2 | +| 〃 | 15㎾ 이하 | 6.0 | 1.8 | +| 〃 | 15㎾ 이상 | 7.0 | 2.5 | +| 4) 팬코일유닛(床置형)풍량 | 510㎥/hr이하 | 1.0 | | +| 〃 | 680㎥/hr이상 | 1.0 | 0.2 | +| 팬코일유닛(天井형) | 510㎥/hr이하 | 1.5 | 0.5 | +| 〃 | 680㎥/hr이상 | 2.0 | 0.5 | +| 5) 윈도우타입 | 0.4㎾이하 | 1.0 | 0.5 | +| 〃 | 0.55㎾ 이하 | 1.3 | 0.5 | +| 〃 | 0.75㎾ 이하 | 1.5 | 1.0 | + + + +[주] +① 조립 및 부속품 설치품을 포함한다. +② 수배관 전기배관품은 포함하지 않았다. +③ 운반품 및 가대는 별도 계상한다. +④ 핸들링유닛설치에는 가열기 또는 냉각기 설치품이 제외되었다. + +### 8-2-4 천장형 에어컨 설치('20년 신설) + +(대당) + +| 구분 | 단위 | 수량 (냉방능력 kW) | | | +|---|---|---|---|---| +| | | 실내기 | 실외기 | | +| | | 16이하 | 6~12이하 | 16이하 | +| 기계설비공 | 인 | 0.45 | 1.00 | 1.33 | +| 보통인부 | 인 | 0.22 | 0.50 | 0.67 | +| 비고 | - 본 품의 실외기는 실내기 1대 연결기준이며, 실내기 추가로 인해 실외기에 배관접합이 추가되는 경우, 실내기 대당 실외기 품의 15%를 가산한다. | | | | + + + +[주] +① 본 품은 천장에 설치하는 에어컨 실내기와 바닥에 상치하는 에어컨 실외기 설치 기준이다. +② 실내기는 위치선정, 앵커 및 달대 설치, 실내기 및 커버 설치, 제어부 결선, 배관접합 작업을 포함한다. +③ 실외기는 위치선정, 실외기 설치, 배관접합, 냉매진공 및 충전, 작동시험을 포함한다. +④ 배관 설치 및 보온, 전기・통신배선 작업은 별도 계상한다. +⑤ 장비(크레인, 냉매가스 충전기 등)는 별도 계상한다. +⑥ 공구손료 및 경장비(전동드릴 등) 기계경비는 인력품의 2%로 계상한다. + +### 8-2-5 전열교환기 설치('20년 신설) + +(대당) + +| 구분 | 단위 | 수량 (풍량 ㎥/h) | | | +|---|---|---|---|---| +| | | 250이하 | 500이하 | 800이하 | +| 기계설비공 | 인 | 0.21 | 0.28 | 0.36 | +| 보통인부 | 인 | 0.12 | 0.16 | 0.20 | + + + +[주] +① 본 품은 천장에 설치하여 덕트와 연결하는 환기시스템(전열교환기) 기준이다. +② 본 품은 앵커 및 달대 설치, 전열교환기 설치, 덕트연결(4구), 제어부 결선, 작동시험을 포함한다. +③ 덕트공사(덕트 설치, 취출구 등) 및 전기・통신배선 작업은 별도 계상한다. +④ 공구손료 및 경장비(전동드릴 등)의 기계경비는 인력품의 2%로 계상한다.