From f07734cf98b0359fe38307dcf30657b0f256f076 Mon Sep 17 00:00:00 2001 From: umsangdon Date: Mon, 16 Nov 2026 11:03:29 +0900 Subject: [PATCH] =?UTF-8?q?chore(ledger):=20=EC=9A=94=EA=B5=AC=20885=20?= =?UTF-8?q?=EC=9E=A5=EB=B6=80=20=E2=80=94=20=EA=B8=B0=EA=B3=84=20=EC=9E=91?= =?UTF-8?q?=EC=97=85=EB=9F=89=20=EB=B0=A9=EC=8B=9D=20=ED=98=91=EC=9D=98=20?= =?UTF-8?q?=EB=8B=B5(=EC=95=88=20=EA=B3=A0=EB=A5=B8=20=EC=AA=BD=20?= =?UTF-8?q?=EC=88=A8=EA=B9=80=20=C2=B7=20=EC=8B=9C=EA=B0=84=EB=8B=B9=20?= =?UTF-8?q?=EC=8B=9D=EC=9D=B4=EB=A9=B4=20=EA=B8=B0=EA=B3=84=20=EC=A7=81?= =?UTF-8?q?=EC=A0=91)?= MIME-Version: 1.0 Content-Type: text/plain; charset=UTF-8 Content-Transfer-Encoding: 8bit Co-Authored-By: Claude --- docs/raw/요구_1104/사용자요구_1104.md | 8 ++++++++ 1 file changed, 8 insertions(+) diff --git a/docs/raw/요구_1104/사용자요구_1104.md b/docs/raw/요구_1104/사용자요구_1104.md index 1f631dd7a..92a8d21e8 100644 --- a/docs/raw/요구_1104/사용자요구_1104.md +++ b/docs/raw/요구_1104/사용자요구_1104.md @@ -1512,3 +1512,11 @@ b09원가에서는 확인할필요 없음. 어차피 m02의정보를 가져가 3. 겹분수 55줄도 분리 4. 대형브레이커는 품셈이 식이 아니라는게 어떤의미인지? 위 내용은 한번에 작업을 진행할 생각. 1번 검토, 2번 대답 후 나와 협의 먼저 + +## 요구 885 (11-16 · 사용자 · 협의 답 — 수식 계산으로 바꾸면 품셈 정보를 안 쓰는 것 · 타입에 따른 기계 규격도 사용자가 기계를 바꾸거나 그대로 씀 · 기계 여럿이면 개별 계산 · 시간당 식에서는 작업량 값을 그냥 넣지 않음 · 처음 = 품셈 지정 시공량 방식 · 대형브레이커는 현재 유지 의견 물음) + +1. 일당 시공량에서 사용자가 수식계산으로 변경한다면 결국은 품셈정보를 사용하지 않고 자기가 알아서 하겠다는거지. 그렇다면 타입선정에 따른 부피결정도 당연히 사용자가 기계를 변경하거나 그냥 사용하게 되겠지. 품셈에서 가이드를 제공했지만 변경하겠다면 사용자가 변경할 수 있어야 함. +2. 기계가 여럿이면 개별 개산이 맞음. +3.시간당 작업량은 품셈에서 표를 선택했을때도 넣을 수 있게되어있음. 하지만 수식으로 시공량을 계산할때는 그냥 넣으면 안될것 같음. +4. 처음 값이라는게 품셈을 기준으로 한 지정된 시공량 방식에서 계산 시작이라면 맞음. +5. 대형 브레이커의 경우 독립적으로 혼자 사용할수 있는 기계가 아니라 드런걸로 보임. 현재를 유지해도 될것같은데 너의 생각은?